Sofar Solar HYD 5KTL-3PH vs Huawei SUN2000L-5KTL
VS
The verdict
SUN2000L-5KTL leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 8 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
8
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 22 parameters
What actually differs
Parameter
HYD 5KTL-3PH
SUN2000L-5KTL
Difference
European efficiency
97.5 %
98.0 %
0.5 pp more efficient
Max DC voltage
1000 V
600 V
400 V apart
Max efficiency
98.0 %
98.6 %
0.6 pp more efficient
Max AC power
5.00 kW
5.50 kW
0.50 kW apart
Weight
32.0 kg
10.6 kg
21.4 kg lighter
Weight per kW
6.4 kg/kW
2.1 kg/kW
4.3 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.0 A
25.0 A
17.0 A apart
Start voltage
200 V
120 V
80 V earlier start
MPPT voltage range
180-960 V
120-480 V
180-960 V vs 120-480 V
Battery voltage
180-800 Vdc
350-450 Vdc
180-800 Vdc vs 350-450 Vdc
Dimensions
515x587x261 mm
375x375x162 mm
515x587x261 mm vs 375x375x162 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
HYD 5KTL-3PH
SUN2000L-5KTL
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.50 kW
0.50 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
8.0 A
25.0 A
17.0 A apart
PV input
Max PV power
7.50 kW
-
Not published by Huawei
DC/AC ratio
1.50
-
Not published by Huawei
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
180-960 V
120-480 V
180-960 V vs 120-480 V
Start voltage
200 V
120 V
-80 V for SUN2000L-5KTL
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
-
11.0 A
Not published by Sofar Solar
Efficiency
European efficiency
97.5 %
98.0 %
+0.5 pp for SUN2000L-5KTL
Max efficiency
98.0 %
98.6 %
+0.6 pp for SUN2000L-5KTL
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
180-800 Vdc
350-450 Vdc
180-800 Vdc vs 350-450 Vdc
Max charge current
-
10 A
Not published by Sofar Solar
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
32.0 kg
10.6 kg
-21.4 kg for SUN2000L-5KTL
Weight per kW
6.4 kg/kW
2.1 kg/kW
-4.3 kg/kW for SUN2000L-5KTL
Dimensions
515x587x261 mm
375x375x162 mm
515x587x261 mm vs 375x375x162 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Sofar Solar HYD 5KTL-3PH vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
10 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Sofar Solar HYD 5KTL-3PH vs SolarEdge SE5000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Sofar Solar HYD 5KTL-3PH vs Growatt MOD 5000TL3-HU
13 differences, the largest is max ac power
Same type, similar size
Huawei
Huawei SUN2000L-5KTL vs Huawei SUN2000-5KTL-L1
12 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.