Sofar Solar HYD 15KTL-3PH vs Growatt WIT 15K-XHU
VS
The verdict
HYD 15KTL-3PH leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 11 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
11
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 24 parameters
What actually differs
Parameter
HYD 15KTL-3PH
WIT 15K-XHU
Difference
European efficiency
97.7 %
97.2 %
0.5 pp more efficient
Max AC power
15.00 kW
16.50 kW
1.50 kW apart
Max PV power
22.50 kW
30.00 kW
7.50 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Weight
39.5 kg
45.0 kg
5.5 kg lighter
Max AC current
23.9 A
50.0 A
26.1 A apart
Weight per kW
2.6 kg/kW
3.0 kg/kW
0.4 kg/kW lighter
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
180-960 V
150-850 V
180-960 V vs 150-850 V
Start voltage
200 V
180 V
20 V earlier start
Battery voltage
180-800 Vdc
120-800V
180-800 Vdc vs 120-800V
Strings per tracker
1
2
1 string apart
Dimensions
515x587x261 mm
456x684x240 mm
515x587x261 mm vs 456x684x240 mm
02
Full specification
Parameter
HYD 15KTL-3PH
WIT 15K-XHU
Difference
AC output
Rated AC power
15.00 kW
15.00 kW
Same
Max AC power
15.00 kW
16.50 kW
1.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
23.9 A
50.0 A
26.1 A apart
PV input
Max PV power
22.50 kW
30.00 kW
7.50 kW apart
DC/AC ratio
1.50
2.00
+0.50 for WIT 15K-XHU
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
180-960 V
150-850 V
180-960 V vs 150-850 V
Start voltage
200 V
180 V
-20 V for WIT 15K-XHU
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
-
40.0 A
Not published by Sofar Solar
Efficiency
European efficiency
97.7 %
97.2 %
+0.5 pp for HYD 15KTL-3PH
Max efficiency
98.2 %
98.1 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
180-800 Vdc
120-800V
180-800 Vdc vs 120-800V
Max charge current
-
55 A
Not published by Sofar Solar
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
39.5 kg
45.0 kg
-5.5 kg for HYD 15KTL-3PH
Weight per kW
2.6 kg/kW
3.0 kg/kW
-0.4 kg/kW for HYD 15KTL-3PH
Dimensions
515x587x261 mm
456x684x240 mm
515x587x261 mm vs 456x684x240 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
55 dB
Not published by Sofar Solar
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Sofar Solar HYD 15KTL-3PH vs Growatt MID 15KTL3-XH
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Sofar Solar HYD 15KTL-3PH vs Growatt MOD 15KTL3-HU
14 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar HYD 15KTL-3PH vs Huawei SUN2000-15K-MB0
12 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.