ESI-12K-T1 vs SUN2000-12KTL-M1 (High current version) 10 of 26 identical Swap Change inverters

Sofar Solar ESI-12K-T1 vs Huawei SUN2000-12KTL-M1 (High current version)

Sofar Solar ESI-12K-T1
Sofar Solar
ESI-12K-T1
12 kW 97.5 % euro Hybrid
VS
Huawei SUN2000-12KTL-M1 (High current version)
Huawei
SUN2000-12KTL-M1 (High current version)
12 kW 98.2 % euro Hybrid
The verdict

16 differences, and they point both ways

The largest is european efficiency: 0.7 pp more efficient. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter ESI-12K-T1 SUN2000-12KTL-M1 (High current version) Difference
European efficiency 97.5 % 98.2 % 0.7 pp more efficient
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 20.0 A 13.5 A 6.5 A more headroom
Max AC power 13.20 kW 12.00 kW 1.20 kW apart
Max PV power 24.00 kW 18.00 kW 6.00 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Max charge current 25 A 17 A 8 A faster charging
Weight 30.0 kg 17.0 kg 13.0 kg lighter
Weight per kW 2.5 kg/kW 1.4 kg/kW 1.1 kg/kW lighter
Max efficiency 98.2 % 98.6 % 0.4 pp more efficient
MPP trackers 3 2 1 tracker more
Max AC current 20.0 A 18.4 A 1.6 A apart
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 160-950 V 140-980 V 160-950 V vs 140-980 V
Battery voltage 350-435 Vdc 600 V ~ 980 V 350-435 Vdc vs 600 V ~ 980 V
Dimensions 440x708x170 mm 470x525x166 mm 440x708x170 mm vs 470x525x166 mm
02

Full specification

Parameter ESI-12K-T1 SUN2000-12KTL-M1 (High current version) Difference
AC output
Rated AC power 12.00 kW 12.00 kW Same
Max AC power 13.20 kW 12.00 kW 1.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 20.0 A 18.4 A 1.6 A apart
PV input
Max PV power 24.00 kW 18.00 kW 6.00 kW apart
DC/AC ratio 2.00 1.50 +0.50 for ESI-12K-T1
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 160-950 V 140-980 V 160-950 V vs 140-980 V
Start voltage 200 V 200 V Same
MPP trackers 3 2 +1 trackers for ESI-12K-T1
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 13.5 A +6.5 A for ESI-12K-T1
Efficiency
European efficiency 97.5 % 98.2 % +0.7 pp for SUN2000-12KTL-M1 (High current version)
Max efficiency 98.2 % 98.6 % +0.4 pp for SUN2000-12KTL-M1 (High current version)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 350-435 Vdc 600 V ~ 980 V 350-435 Vdc vs 600 V ~ 980 V
Max charge current 25 A 17 A +8 A for ESI-12K-T1
Backup power - 3.3 kW Not published by Sofar Solar
Physical
Weight 30.0 kg 17.0 kg -13.0 kg for SUN2000-12KTL-M1 (High current version)
Weight per kW 2.5 kg/kW 1.4 kg/kW -1.1 kg/kW for SUN2000-12KTL-M1 (High current version)
Dimensions 440x708x170 mm 470x525x166 mm 440x708x170 mm vs 470x525x166 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Sofar Solar
Ethernet - Yes Not published by Sofar Solar
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Sofar Solar ESI-12K-T1 vs Growatt MID 12KTL3-XH
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar ESI-12K-T1 vs Huawei SUN5000-12K-MAP0
14 differences, the largest is european efficiency
Same type, similar size
Huawei
Sofar Solar ESI-12K-T1 vs Huawei SUN2000-12K-MAP0
14 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000-12KTL-M1 (High current version) vs Huawei SUN2000-12KTL-M1
The same specification on paper
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.