SMA Solar STP5.0-3AV-40 (Sunny Tripower 5.0) vs Solis-3P5K-4G

SMA Solar
STP5.0-3AV-40 (Sunny Tripower 5.0)
5 kW
97.4 % euro
Grid-tie
VS
The verdict
10 differences, and they point both ways
The largest is max dc voltage: 150 V apart. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
10
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 20 parameters
What actually differs
Parameter
STP5.0-3AV-40 (Sunny Tripower 5.0)
Solis-3P5K-4G
Difference
Max DC voltage
850 V
1000 V
150 V apart
European efficiency
97.4 %
97.8 %
0.4 pp more efficient
Max AC power
5.00 kW
5.50 kW
0.50 kW apart
Max PV power
9.00 kW
6.00 kW
3.00 kW apart
DC/AC ratio
1.80
1.20
0.60 more oversizing headroom
Nominal AC voltage
230 V
400 V
170 V apart
Weight
17.0 kg
18.0 kg
1.0 kg lighter
Weight per kW
3.4 kg/kW
3.6 kg/kW
0.2 kg/kW lighter
MPPT voltage range
140-800 V
160-850 V
140-800 V vs 160-850 V
Dimensions
470x435x176 mm
563x310x219 mm
470x435x176 mm vs 563x310x219 mm
02
Full specification
Parameter
STP5.0-3AV-40 (Sunny Tripower 5.0)
Solis-3P5K-4G
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.00 kW
5.50 kW
0.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
7.6 A
7.9 A
Effectively the same
PV input
Max PV power
9.00 kW
6.00 kW
3.00 kW apart
DC/AC ratio
1.80
1.20
+0.60 for STP5.0-3AV-40 (Sunny Tripower 5.0)
Max DC voltage
850 V
1000 V
150 V apart
MPPT voltage range
140-800 V
160-850 V
140-800 V vs 160-850 V
Start voltage
175 V
180 V
Effectively the same
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Ginlong Solis
Max input current per tracker
12.0 A
-
Not published by Ginlong Solis
Efficiency
European efficiency
97.4 %
97.8 %
+0.4 pp for Solis-3P5K-4G
Max efficiency
98.2 %
98.3 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
17.0 kg
18.0 kg
-1.0 kg for STP5.0-3AV-40 (Sunny Tripower 5.0)
Weight per kW
3.4 kg/kW
3.6 kg/kW
-0.2 kg/kW for STP5.0-3AV-40 (Sunny Tripower 5.0)
Dimensions
470x435x176 mm
563x310x219 mm
470x435x176 mm vs 563x310x219 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
-
Not published by Ginlong Solis
Noise
30 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by SMA Solar
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SMA Solar STP5.0-3AV-40 (Sunny Tripower 5.0) vs SolarEdge SE5000H (HD‑Wave, single phase)
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
SMA Solar STP5.0-3AV-40 (Sunny Tripower 5.0) vs SolarEdge EV Charging Single Phase Inverter SE5000H (aka H5000SE / SE5000H)
11 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar STP5.0-3AV-40 (Sunny Tripower 5.0) vs Ginlong Solis S6-GR3P-5K02-NV-ND
11 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Solis-3P5K-4G vs GoodWe GW5K-DT
6 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.