STP4.0-3AV-40 (Sunny Tripower 4.0)
vs
SolarEdge SE4000H (HD‑Wave, single phase)
8 of 20 identical
Swap
Change inverters
SMA Solar STP4.0-3AV-40 (Sunny Tripower 4.0) vs SolarEdge SE4000H (HD‑Wave, single phase)

SMA Solar
STP4.0-3AV-40 (Sunny Tripower 4.0)
4 kW
97.1 % euro
Grid-tie
VS
SolarEdge
SolarEdge SE4000H (HD‑Wave, single phase)
4 kW
98.8 % euro
Grid-tie
The verdict
SolarEdge SE4000H (HD‑Wave, single phase) leads on the differences that matter
The largest is european efficiency: 1.7 pp more efficient. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
STP4.0-3AV-40 (Sunny Tripower 4.0)
SolarEdge SE4000H (HD‑Wave, single phase)
Difference
European efficiency
97.1 %
98.8 %
1.7 pp more efficient
Warranty
5 yrs
25 yrs
20 yrs longer
Max DC voltage
850 V
480 V
370 V apart
Max efficiency
98.2 %
99.2 %
1.0 pp more efficient
Max PV power
8.00 kW
6.20 kW
1.80 kW apart
DC/AC ratio
2.00
1.55
0.45 more oversizing headroom
Weight
17.0 kg
9.0 kg
8.0 kg lighter
Weight per kW
4.2 kg/kW
2.2 kg/kW
2.0 kg/kW lighter
Noise
30 dB
25 dB
5 dB quieter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Max AC current
6.1 A
18.5 A
12.4 A apart
Dimensions
470x435x176 mm
280x370x142 mm
470x435x176 mm vs 280x370x142 mm
02
Full specification
Parameter
STP4.0-3AV-40 (Sunny Tripower 4.0)
SolarEdge SE4000H (HD‑Wave, single phase)
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.00 kW
4.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
230 V
230 V
Same
Max AC current
6.1 A
18.5 A
12.4 A apart
PV input
Max PV power
8.00 kW
6.20 kW
1.80 kW apart
DC/AC ratio
2.00
1.55
+0.45 for STP4.0-3AV-40 (Sunny Tripower 4.0)
Max DC voltage
850 V
480 V
370 V apart
MPPT voltage range
140-800 V
-
Not published by SolarEdge
Start voltage
175 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
12.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.1 %
98.8 %
+1.7 pp for SolarEdge SE4000H (HD‑Wave, single phase)
Max efficiency
98.2 %
99.2 %
+1.0 pp for SolarEdge SE4000H (HD‑Wave, single phase)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
17.0 kg
9.0 kg
-8.0 kg for SolarEdge SE4000H (HD‑Wave, single phase)
Weight per kW
4.2 kg/kW
2.2 kg/kW
-2.0 kg/kW for SolarEdge SE4000H (HD‑Wave, single phase)
Dimensions
470x435x176 mm
280x370x142 mm
470x435x176 mm vs 280x370x142 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
30 dB
25 dB
-5 dB for SolarEdge SE4000H (HD‑Wave, single phase)
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by SMA Solar
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
5 yrs
25 yrs
+20 yrs for SolarEdge SE4000H (HD‑Wave, single phase)
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
SMA Solar STP4.0-3AV-40 (Sunny Tripower 4.0) vs SolarEdge EV Charging Single Phase Inverter SE4000H (aka H4000SE / SE4000H)
9 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar STP4.0-3AV-40 (Sunny Tripower 4.0) vs Solis-3P4K-4G
8 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar STP4.0-3AV-40 (Sunny Tripower 4.0) vs Ginlong Solis S6-GR3P-4K02-NV-ND
11 differences, the largest is european efficiency
Same type, similar size
GoodWe
SolarEdge SE4000H (HD‑Wave, single phase) vs GoodWe GW4K-DT
11 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.