SMA Solar STP10.0-3AV-40 vs Sungrow SG10KTL-M
VS
The verdict
STP10.0-3AV-40 leads on the differences that matter
The largest is max dc voltage: 100 V apart. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
10
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 20 parameters
What actually differs
Parameter
STP10.0-3AV-40
SG10KTL-M
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
20.0 A
11.0 A
9.0 A more headroom
Max efficiency
98.3 %
98.6 %
0.3 pp more efficient
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
14.5 A
16.5 A
2.0 A apart
Start voltage
175 V
250 V
75 V earlier start
MPPT voltage range
260-800 V
200-1000 V
260-800 V vs 200-1000 V
Weight
20.5 kg
20.0 kg
0.5 kg lighter
Strings per tracker
2
1
1 string apart
Dimensions
497x460x176 mm
485x370x160 mm
497x460x176 mm vs 485x370x160 mm
02
Full specification
Parameter
STP10.0-3AV-40
SG10KTL-M
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
10.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
14.5 A
16.5 A
2.0 A apart
PV input
Max PV power
15.00 kW
-
Not published by Sungrow
DC/AC ratio
1.50
-
Not published by Sungrow
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
260-800 V
200-1000 V
260-800 V vs 200-1000 V
Start voltage
175 V
250 V
-75 V for STP10.0-3AV-40
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
20.0 A
11.0 A
+9.0 A for STP10.0-3AV-40
Efficiency
European efficiency
98.0 %
98.1 %
Effectively the same
Max efficiency
98.3 %
98.6 %
+0.3 pp for SG10KTL-M
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
20.5 kg
20.0 kg
-0.5 kg for SG10KTL-M
Weight per kW
2.0 kg/kW
2.0 kg/kW
Same
Dimensions
497x460x176 mm
485x370x160 mm
497x460x176 mm vs 485x370x160 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
30 dB
-
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
Yes
-
Not published by Sungrow
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SMA Solar STP10.0-3AV-40 vs Growatt MOD 10KTL3-X2(Pro)
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
SMA Solar STP10.0-3AV-40 vs Growatt MOD 10KTL3-X
11 differences, the largest is max dc voltage
Same type, similar size
Sungrow
SMA Solar STP10.0-3AV-40 vs Sungrow SG10RT-20
11 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Sungrow SG10KTL-M vs SOFAR 11KTLX-G3
7 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.