SMA Solar STP 30-US-50 (Sunny Tripower X-US 30) vs Growatt MID 30KTL3-X
VS
The verdict
11 differences, and they point both ways
The largest is warranty: 5 yrs longer. 12 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
12
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 23 parameters
What actually differs
Parameter
STP 30-US-50 (Sunny Tripower X-US 30)
MID 30KTL3-X
Difference
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
24.0 A
26.0 A
2.0 A more headroom
Max AC power
30.00 kW
33.30 kW
3.30 kW apart
Weight
35.0 kg
29.5 kg
5.5 kg lighter
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
36.0 A
50.5 A
14.5 A apart
Start voltage
188 V
250 V
62 V earlier start
Ingress protection
Type 4X (UL 50E)
IP66
Type 4X (UL 50E) vs IP66
MPPT voltage range
150-1000 V
200-1000 V
150-1000 V vs 200-1000 V
Dimensions
762x728x266 mm
435x580x230 mm
762x728x266 mm vs 435x580x230 mm
02
Full specification
Parameter
STP 30-US-50 (Sunny Tripower X-US 30)
MID 30KTL3-X
Difference
AC output
Rated AC power
30.00 kW
30.00 kW
Same
Max AC power
30.00 kW
33.30 kW
3.30 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
36.0 A
50.5 A
14.5 A apart
PV input
Max PV power
45.00 kW
45.00 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
150-1000 V
200-1000 V
150-1000 V vs 200-1000 V
Start voltage
188 V
250 V
-62 V for STP 30-US-50 (Sunny Tripower X-US 30)
MPP trackers
3
-
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
24.0 A
26.0 A
+2.0 A for MID 30KTL3-X
Efficiency
European efficiency
-
98.5 %
Not published by SMA Solar
Max efficiency
-
98.8 %
Not published by SMA Solar
CEC efficiency
98.0 %
-
Not published by Growatt
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
35.0 kg
29.5 kg
-5.5 kg for MID 30KTL3-X
Weight per kW
1.2 kg/kW
1.0 kg/kW
Effectively the same
Dimensions
762x728x266 mm
435x580x230 mm
762x728x266 mm vs 435x580x230 mm
Ingress protection
Type 4X (UL 50E)
IP66
Type 4X (UL 50E) vs IP66
Cooling
forced-air
forced-air
Same
Noise
59 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for STP 30-US-50 (Sunny Tripower X-US 30)
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SMA Solar STP 30-US-50 (Sunny Tripower X-US 30) vs Growatt MID 30KTL3-X2 (Pro.E)
11 differences, the largest is warranty
Same type, similar size
Growatt
SMA Solar STP 30-US-50 (Sunny Tripower X-US 30) vs Growatt MID 30KTL3-X2-1
10 differences, the largest is warranty
Same type, similar size
GoodWe
SMA Solar STP 30-US-50 (Sunny Tripower X-US 30) vs GoodWe GW30K-MT
9 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MID 30KTL3-X vs Huawei SUN2000-33KTL-A
9 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.