SMA Solar SI8.0H-13 vs Growatt SPF 6000T DVM-MPV
VS
The verdict
10 differences, and they point both ways
The largest is max dc voltage: 187 V apart. 2 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
2
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 12 parameters
What actually differs
Parameter
SI8.0H-13
SPF 6000T DVM-MPV
Difference
Max DC voltage
63 V
250 V
187 V apart
Max efficiency
95.8 %
85.0 %
10.8 pp more efficient
Max AC power
11.00 kW
6.00 kW
5.00 kW apart
Weight
63.0 kg
52.0 kg
11.0 kg lighter
Weight per kW
10.5 kg/kW
8.7 kg/kW
1.8 kg/kW lighter
Max operating temperature
60 °C
45 °C
15 °C more heat tolerant
Ingress protection
IP54
IP20
IP54 vs IP20
Nominal AC voltage
230 V
240 V
10 V apart
MPPT voltage range
41-63 V
60-245 V
41-63 V vs 60-245 V
Dimensions
612x467x242 mm
540x360x218 mm
612x467x242 mm vs 540x360x218 mm
02
Full specification
Parameter
SI8.0H-13
SPF 6000T DVM-MPV
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
11.00 kW
6.00 kW
5.00 kW apart
Grid connection
Single-phase
-
Not published by Growatt
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
120.0 A
-
Not published by Growatt
PV input
Max PV power
-
5.00 kW
Not published by SMA Solar
DC/AC ratio
-
0.83
Not published by SMA Solar
Max DC voltage
63 V
250 V
187 V apart
MPPT voltage range
41-63 V
60-245 V
41-63 V vs 60-245 V
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
95.8 %
85.0 %
+10.8 pp for SI8.0H-13
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
41-63 V (48 V nominal)
-
Not published by Growatt
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
63.0 kg
52.0 kg
-11.0 kg for SPF 6000T DVM-MPV
Weight per kW
10.5 kg/kW
8.7 kg/kW
-1.8 kg/kW for SPF 6000T DVM-MPV
Dimensions
612x467x242 mm
540x360x218 mm
612x467x242 mm vs 540x360x218 mm
Ingress protection
IP54
IP20
IP54 vs IP20
Cooling
-
-
Neither datasheet publishes this
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
45 °C
+15 °C for SI8.0H-13
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
10 yrs
-
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
SMA Solar SI8.0H-13 vs Growatt SPF 6000T DVM
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
SMA Solar SI8.0H-13 vs Growatt SPF 6000T DVM-G2
12 differences, the largest is warranty
Same type, similar size
Growatt
SMA Solar SI8.0H-13 vs Growatt SPF 6000 ES Plus
10 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

