Skip to main content
SB3.0-1AV-41 (Sunny Boy 3.0) vs MOD 3000TL3-X 9 of 25 identical Swap Change inverters

SMA Solar SB3.0-1AV-41 (Sunny Boy 3.0) vs Growatt MOD 3000TL3-X

SMA Solar SB3.0-1AV-41 (Sunny Boy 3.0)
SMA Solar
SB3.0-1AV-41 (Sunny Boy 3.0)
3 kW 96.4 % euro Grid-tie
VS
Growatt MOD 3000TL3-X
Growatt
MOD 3000TL3-X
3 kW 97.5 % euro Grid-tie
The verdict

MOD 3000TL3-X leads on the differences that matter

The largest is european efficiency: 1.1 pp more efficient. 9 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
9 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 25 parameters
Parameter SB3.0-1AV-41 (Sunny Boy 3.0) MOD 3000TL3-X Difference
European efficiency 96.4 % 97.5 % 1.1 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 15.0 A 13.0 A 2.0 A more headroom
Max efficiency 97.0 % 98.3 % 1.3 pp more efficient
Max PV power 5.50 kW 4.50 kW 1.00 kW apart
DC/AC ratio 1.83 1.50 0.33 more oversizing headroom
Weight 17.5 kg 12.5 kg 5.0 kg lighter
Weight per kW 5.8 kg/kW 4.2 kg/kW 1.7 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 13.7 A 5.0 A 8.7 A apart
Start voltage 125 V 160 V 35 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 110-500 V 140-1000 V 110-500 V vs 140-1000 V
Strings per tracker 2 1 1 string apart
Dimensions 470x435x176 mm 387x425x147 mm 470x435x176 mm vs 387x425x147 mm
02

Full specification

Parameter SB3.0-1AV-41 (Sunny Boy 3.0) MOD 3000TL3-X Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.00 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 13.7 A 5.0 A 8.7 A apart
PV input
Max PV power 5.50 kW 4.50 kW 1.00 kW apart
DC/AC ratio 1.83 1.50 +0.33 for SB3.0-1AV-41 (Sunny Boy 3.0)
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 110-500 V 140-1000 V 110-500 V vs 140-1000 V
Start voltage 125 V 160 V -35 V for SB3.0-1AV-41 (Sunny Boy 3.0)
MPP trackers 2 2 Same
Strings per tracker 2 1 1 string apart
Max input current per tracker 15.0 A 13.0 A +2.0 A for SB3.0-1AV-41 (Sunny Boy 3.0)
Efficiency
European efficiency 96.4 % 97.5 % +1.1 pp for MOD 3000TL3-X
Max efficiency 97.0 % 98.3 % +1.3 pp for MOD 3000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 17.5 kg 12.5 kg -5.0 kg for MOD 3000TL3-X
Weight per kW 5.8 kg/kW 4.2 kg/kW -1.7 kg/kW for MOD 3000TL3-X
Dimensions 470x435x176 mm 387x425x147 mm 470x435x176 mm vs 387x425x147 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise 25 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
SMA Solar SB3.0-1AV-41 (Sunny Boy 3.0) vs SolarEdge SE3000H (HD‑Wave, single phase)
9 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar SB3.0-1AV-41 (Sunny Boy 3.0) vs Solis-3P3K-4G
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
SMA Solar SB3.0-1AV-41 (Sunny Boy 3.0) vs Ginlong Solis S6-GR3P-3K02-NV-ND
16 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-X vs Growatt MOD 3000TL3-X2 (Pro)
5 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.