Skip to main content
SUN5000-12K-MAP0 vs SUN-12K-SG01HP3-EU-AM2 11 of 28 identical Swap Change inverters

Huawei SUN5000-12K-MAP0 vs Deye SUN-12K-SG01HP3-EU-AM2

Huawei SUN5000-12K-MAP0
Huawei
SUN5000-12K-MAP0
12 kW 98.2 % euro Hybrid
VS
Deye SUN-12K-SG01HP3-EU-AM2
Deye
SUN-12K-SG01HP3-EU-AM2
12 kW 97.0 % euro Hybrid
The verdict

SUN5000-12K-MAP0 leads on the differences that matter

The largest is european efficiency: 1.2 pp more efficient. 11 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
11 of 28 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 28 parameters
Parameter SUN5000-12K-MAP0 SUN-12K-SG01HP3-EU-AM2 Difference
European efficiency 98.2 % 97.0 % 1.2 pp more efficient
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 16.0 A 26.0 A 10.0 A more headroom
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max PV power 22.00 kW 15.60 kW 6.40 kW apart
DC/AC ratio 1.83 1.30 0.53 more oversizing headroom
Max charge current 20 A 50 A 30 A faster charging
Weight 21.0 kg 30.5 kg 9.5 kg lighter
Noise 29 dB 55 dB 26 dB quieter
Weight per kW 1.8 kg/kW 2.5 kg/kW 0.8 kg/kW lighter
Max AC current 20.2 A 21.9 A 1.7 A apart
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 160-1000 V 150-850 V 160-1000 V vs 150-850 V
Start voltage 160 V 180 V 20 V earlier start
Battery voltage 600-980 V 160-700 600-980 V vs 160-700
Strings per tracker 1 2 1 string apart
Dimensions 490x460x130 mm 638x408x237 mm 490x460x130 mm vs 638x408x237 mm
02

Full specification

Parameter SUN5000-12K-MAP0 SUN-12K-SG01HP3-EU-AM2 Difference
AC output
Rated AC power 12.00 kW 12.00 kW Same
Max AC power 13.20 kW 13.20 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 20.2 A 21.9 A 1.7 A apart
PV input
Max PV power 22.00 kW 15.60 kW 6.40 kW apart
DC/AC ratio 1.83 1.30 +0.53 for SUN5000-12K-MAP0
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 160-1000 V 150-850 V 160-1000 V vs 150-850 V
Start voltage 160 V 180 V -20 V for SUN5000-12K-MAP0
MPP trackers 2 2 Same
Strings per tracker 1 2 1 string apart
Max input current per tracker 16.0 A 26.0 A +10.0 A for SUN-12K-SG01HP3-EU-AM2
Efficiency
European efficiency 98.2 % 97.0 % +1.2 pp for SUN5000-12K-MAP0
Max efficiency 98.6 % 97.6 % +1.0 pp for SUN5000-12K-MAP0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 160-700 600-980 V vs 160-700
Max charge current 20 A 50 A +30 A for SUN-12K-SG01HP3-EU-AM2
Backup power - - Neither datasheet publishes this
Physical
Weight 21.0 kg 30.5 kg -9.5 kg for SUN5000-12K-MAP0
Weight per kW 1.8 kg/kW 2.5 kg/kW -0.8 kg/kW for SUN5000-12K-MAP0
Dimensions 490x460x130 mm 638x408x237 mm 490x460x130 mm vs 638x408x237 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise 29 dB 55 dB -26 dB for SUN5000-12K-MAP0
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by Deye
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Huawei SUN5000-12K-MAP0 vs Growatt MID 12KTL3-XH
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN5000-12K-MAP0 vs Huawei SUN2000-12KTL-M1 (High current version)
13 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN5000-12K-MAP0 vs Huawei SUN2000-12K-MAP0
The same specification on paper
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.