Skip to main content
SUN2000L-5KTL vs S6-EH3P5K-H-EU 6 of 21 identical Swap Change inverters

Huawei SUN2000L-5KTL vs Ginlong Solis S6-EH3P5K-H-EU

Huawei SUN2000L-5KTL
Huawei
SUN2000L-5KTL
5 kW 98.0 % euro Hybrid
VS
Ginlong Solis S6-EH3P5K-H-EU
Ginlong Solis
S6-EH3P5K-H-EU
5 kW Hybrid
The verdict

SUN2000L-5KTL leads on the differences that matter

The largest is max dc voltage: 400 V apart. 6 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
6 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 21 parameters
Parameter SUN2000L-5KTL S6-EH3P5K-H-EU Difference
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 11.0 A 16.0 A 5.0 A more headroom
Max efficiency 98.6 % 96.5 % 2.1 pp more efficient
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Max charge current 10 A 50 A 40 A faster charging
Weight 10.6 kg 27.6 kg 17.0 kg lighter
Weight per kW 2.1 kg/kW 5.5 kg/kW 3.4 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 25.0 A 7.6 A 17.4 A apart
Start voltage 120 V 160 V 40 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 120-480 V 200-850 V 120-480 V vs 200-850 V
Battery voltage 350-450 Vdc 120-600 V (note: supports max battery voltage up to 700 V) 350-450 Vdc vs 120-600 V (note: supports max battery voltage up to 700 V)
Dimensions 375x375x162 mm 500x600x210 mm 375x375x162 mm vs 500x600x210 mm
02

Full specification

Parameter SUN2000L-5KTL S6-EH3P5K-H-EU Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 25.0 A 7.6 A 17.4 A apart
PV input
Max PV power - 10.00 kW Not published by Huawei
DC/AC ratio - 2.00 Not published by Huawei
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 120-480 V 200-850 V 120-480 V vs 200-850 V
Start voltage 120 V 160 V -40 V for SUN2000L-5KTL
MPP trackers 2 - Not published by Ginlong Solis
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 16.0 A +5.0 A for S6-EH3P5K-H-EU
Efficiency
European efficiency 98.0 % - Not published by Ginlong Solis
Max efficiency 98.6 % 96.5 % +2.1 pp for SUN2000L-5KTL
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 350-450 Vdc 120-600 V (note: supports max battery voltage up to 700 V) 350-450 Vdc vs 120-600 V (note: supports max battery voltage up to 700 V)
Max charge current 10 A 50 A +40 A for S6-EH3P5K-H-EU
Backup power - - Neither datasheet publishes this
Physical
Weight 10.6 kg 27.6 kg -17.0 kg for SUN2000L-5KTL
Weight per kW 2.1 kg/kW 5.5 kg/kW -3.4 kg/kW for SUN2000L-5KTL
Dimensions 375x375x162 mm 500x600x210 mm 375x375x162 mm vs 500x600x210 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 47 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000L-5KTL vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
8 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Huawei SUN2000L-5KTL vs SolarEdge SE5000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000L-5KTL vs Growatt MOD 5000TL3-HU
15 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.