Huawei SUN2000L-5KTL vs Fronius Primo GEN24 5.0 208-240 [Plus]
VS
![Fronius Primo GEN24 5.0 208-240 [Plus]](/static/images/inverters/fronius-international/fronius-primo-gen24.webp)
Fronius International
Fronius Primo GEN24 5.0 208-240 [Plus]
5 kW
Hybrid
The verdict
SUN2000L-5KTL leads on the differences that matter
The largest is max efficiency: 1.0 pp more efficient. 8 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
8
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 21 parameters
What actually differs
Parameter
SUN2000L-5KTL
Fronius Primo GEN24 5.0 208-240 [Plus]
Difference
Max efficiency
98.6 %
97.6 %
1.0 pp more efficient
Max AC power
5.50 kW
5.00 kW
0.50 kW apart
Max charge current
10 A
22 A
12 A faster charging
Weight
10.6 kg
15.1 kg
4.5 kg lighter
Weight per kW
2.1 kg/kW
3.0 kg/kW
0.9 kg/kW lighter
Start voltage
120 V
80 V
40 V earlier start
Ingress protection
IP65
Type 4X
IP65 vs Type 4X
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
25.0 A
24.0 A
1.0 A apart
MPPT voltage range
120-480 V
200-480 V
120-480 V vs 200-480 V
Battery voltage
350-450 Vdc
150-455 Vdc
350-450 Vdc vs 150-455 Vdc
Dimensions
375x375x162 mm
518x474x164 mm
375x375x162 mm vs 518x474x164 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000L-5KTL
Fronius Primo GEN24 5.0 208-240 [Plus]
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.50 kW
5.00 kW
0.50 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
240 V
10 V apart
Max AC current
25.0 A
24.0 A
1.0 A apart
PV input
Max PV power
-
5.15 kW
Not published by Huawei
DC/AC ratio
-
1.03
Not published by Huawei
Max DC voltage
600 V
600 V
Same
MPPT voltage range
120-480 V
200-480 V
120-480 V vs 200-480 V
Start voltage
120 V
80 V
-40 V for Fronius Primo GEN24 5.0 208-240 [Plus]
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Fronius International
Max input current per tracker
11.0 A
-
Not published by Fronius International
Efficiency
European efficiency
98.0 %
-
Not published by Fronius International
Max efficiency
98.6 %
97.6 %
+1.0 pp for SUN2000L-5KTL
CEC efficiency
-
97.0 %
Not published by Huawei
Battery
Battery input
Yes
Yes
Same
Battery voltage
350-450 Vdc
150-455 Vdc
350-450 Vdc vs 150-455 Vdc
Max charge current
10 A
22 A
+12 A for Fronius Primo GEN24 5.0 208-240 [Plus]
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.6 kg
15.1 kg
-4.5 kg for SUN2000L-5KTL
Weight per kW
2.1 kg/kW
3.0 kg/kW
-0.9 kg/kW for SUN2000L-5KTL
Dimensions
375x375x162 mm
518x474x164 mm
375x375x162 mm vs 518x474x164 mm
Ingress protection
IP65
Type 4X
IP65 vs Type 4X
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Huawei
Arc fault protection
-
Yes
Not published by Huawei
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000L-5KTL vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
8 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Huawei SUN2000L-5KTL vs SolarEdge SE5000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000L-5KTL vs Growatt MOD 5000TL3-HU
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.