Skip to main content
SUN2000L-3KTL vs MOD 3000TL3-HU 9 of 24 identical Swap Change inverters

Huawei SUN2000L-3KTL vs Growatt MOD 3000TL3-HU

Huawei SUN2000L-3KTL
Huawei
SUN2000L-3KTL
3 kW 97.6 % euro Hybrid
VS
Growatt MOD 3000TL3-HU
Growatt
MOD 3000TL3-HU
3 kW 97.8 % euro Hybrid
The verdict

15 differences, and they point both ways

The largest is max dc voltage: 400 V apart. 9 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
9 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 24 parameters
Parameter SUN2000L-3KTL MOD 3000TL3-HU Difference
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 11.0 A 20.0 A 9.0 A more headroom
Max charge current 10 A 25 A 15 A faster charging
Weight 10.6 kg 19.0 kg 8.4 kg lighter
Weight per kW 3.5 kg/kW 6.3 kg/kW 2.8 kg/kW lighter
European efficiency 97.6 % 97.8 % 0.2 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 15.0 A 5.0 A 10.0 A apart
Start voltage 120 V 180 V 60 V earlier start
Max efficiency 98.5 % 98.3 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 120-480 V 140-1000 V 120-480 V vs 140-1000 V
Battery voltage 350-450 Vdc 600-980 V 350-450 Vdc vs 600-980 V
Dimensions 375x375x162 mm 468x408x202 mm 375x375x162 mm vs 468x408x202 mm
02

Full specification

Parameter SUN2000L-3KTL MOD 3000TL3-HU Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.30 kW 3.30 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 15.0 A 5.0 A 10.0 A apart
PV input
Max PV power - 6.00 kW Not published by Huawei
DC/AC ratio - 2.00 Not published by Huawei
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 120-480 V 140-1000 V 120-480 V vs 140-1000 V
Start voltage 120 V 180 V -60 V for SUN2000L-3KTL
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 20.0 A +9.0 A for MOD 3000TL3-HU
Efficiency
European efficiency 97.6 % 97.8 % +0.2 pp for MOD 3000TL3-HU
Max efficiency 98.5 % 98.3 % +0.2 pp for SUN2000L-3KTL
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 350-450 Vdc 600-980 V 350-450 Vdc vs 600-980 V
Max charge current 10 A 25 A +15 A for MOD 3000TL3-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 10.6 kg 19.0 kg -8.4 kg for SUN2000L-3KTL
Weight per kW 3.5 kg/kW 6.3 kg/kW -2.8 kg/kW for SUN2000L-3KTL
Dimensions 375x375x162 mm 468x408x202 mm 375x375x162 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 29 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Huawei
Integrated DC switch Yes Yes Same
Warranty
Warranty - 10 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000L-3KTL vs SolarEdge SE3000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000L-3KTL vs Growatt SPM 3000TL-HU
11 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Huawei SUN2000L-3KTL vs Growatt MOD 3000TL3-XH
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.