Huawei SUN2000L-3.68KTL vs Fronius Primo GEN24 3.6
VS
Fronius International
Fronius Primo GEN24 3.6
3.68 kW
97.0 % euro
Hybrid
The verdict
SUN2000L-3.68KTL leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 10 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
10
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 24 parameters
What actually differs
Parameter
SUN2000L-3.68KTL
Fronius Primo GEN24 3.6
Difference
European efficiency
97.8 %
97.0 %
0.8 pp more efficient
Max input current per tracker
11.0 A
22.0 A
11.0 A more headroom
Max efficiency
98.5 %
97.6 %
0.9 pp more efficient
Max charge current
10 A
22 A
12 A faster charging
Weight
10.6 kg
15.4 kg
4.8 kg lighter
Weight per kW
2.9 kg/kW
4.2 kg/kW
1.3 kg/kW lighter
Start voltage
120 V
80 V
40 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
120-480 V
65-530 V
120-480 V vs 65-530 V
Battery voltage
350-450 Vdc
150-455 V
350-450 Vdc vs 150-455 V
Max AC current
16.0 A
16.7 A
0.7 A apart
Strings per tracker
1
2
1 string apart
Dimensions
375x375x162 mm
530x474x165 mm
375x375x162 mm vs 530x474x165 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000L-3.68KTL
Fronius Primo GEN24 3.6
Difference
AC output
Rated AC power
3.68 kW
3.68 kW
Same
Max AC power
3.68 kW
3.68 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
16.0 A
16.7 A
0.7 A apart
PV input
Max PV power
-
3.81 kW
Not published by Huawei
DC/AC ratio
-
1.03
Not published by Huawei
Max DC voltage
600 V
600 V
Same
MPPT voltage range
120-480 V
65-530 V
120-480 V vs 65-530 V
Start voltage
120 V
80 V
-40 V for Fronius Primo GEN24 3.6
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
11.0 A
22.0 A
+11.0 A for Fronius Primo GEN24 3.6
Efficiency
European efficiency
97.8 %
97.0 %
+0.8 pp for SUN2000L-3.68KTL
Max efficiency
98.5 %
97.6 %
+0.9 pp for SUN2000L-3.68KTL
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
350-450 Vdc
150-455 V
350-450 Vdc vs 150-455 V
Max charge current
10 A
22 A
+12 A for Fronius Primo GEN24 3.6
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.6 kg
15.4 kg
-4.8 kg for SUN2000L-3.68KTL
Weight per kW
2.9 kg/kW
4.2 kg/kW
-1.3 kg/kW for SUN2000L-3.68KTL
Dimensions
375x375x162 mm
530x474x165 mm
375x375x162 mm vs 530x474x165 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
42 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Huawei
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000L-3.68KTL vs SolarEdge SE3680H
6 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Huawei SUN2000L-3.68KTL vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE3680H / H3680SE
6 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000L-3.68KTL vs Huawei SUN2000-3.68KTL-L1
9 differences, the largest is european efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.