Huawei SUN2000-6KTL-M1 vs Sungrow SH6.0RT-20
VS
The verdict
13 differences, and they point both ways
The largest is max dc voltage: 100 V apart. 14 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
14
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 27 parameters
What actually differs
Parameter
SUN2000-6KTL-M1
SH6.0RT-20
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
11.0 A
13.5 A
2.5 A more headroom
Max AC power
6.60 kW
6.00 kW
0.60 kW apart
Max charge current
16 A
30 A
14 A faster charging
Weight
17.0 kg
27.0 kg
10.0 kg lighter
Weight per kW
2.8 kg/kW
4.5 kg/kW
1.7 kg/kW lighter
Max efficiency
98.6 %
98.2 %
0.4 pp more efficient
European efficiency
97.7 %
97.5 %
0.2 pp more efficient
Max AC current
10.1 A
9.1 A
1.0 A apart
MPPT voltage range
140-980 V
150-950 V
140-980 V vs 150-950 V
Start voltage
200 V
180 V
20 V earlier start
Battery voltage
600 V ~ 980 V
150-600 V
600 V ~ 980 V vs 150-600 V
Dimensions
525x470x146 mm
540x460x170 mm
525x470x146 mm vs 540x460x170 mm
02
Full specification
Parameter
SUN2000-6KTL-M1
SH6.0RT-20
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.60 kW
6.00 kW
0.60 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
10.1 A
9.1 A
1.0 A apart
PV input
Max PV power
9.00 kW
9.00 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
140-980 V
150-950 V
140-980 V vs 150-950 V
Start voltage
200 V
180 V
-20 V for SH6.0RT-20
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
11.0 A
13.5 A
+2.5 A for SH6.0RT-20
Efficiency
European efficiency
97.7 %
97.5 %
+0.2 pp for SUN2000-6KTL-M1
Max efficiency
98.6 %
98.2 %
+0.4 pp for SUN2000-6KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600 V ~ 980 V
150-600 V
600 V ~ 980 V vs 150-600 V
Max charge current
16 A
30 A
+14 A for SH6.0RT-20
Backup power
3.3 kW
-
Not published by Sungrow
Physical
Weight
17.0 kg
27.0 kg
-10.0 kg for SUN2000-6KTL-M1
Weight per kW
2.8 kg/kW
4.5 kg/kW
-1.7 kg/kW for SUN2000-6KTL-M1
Dimensions
525x470x146 mm
540x460x170 mm
525x470x146 mm vs 540x460x170 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-M1 vs SolarEdge SE6000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-M1 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.