Huawei SUN2000-6KTL-M1 vs SolarEdge SE10K (Three Phase, Delta Grids)
VS

SolarEdge
SE10K (Three Phase, Delta Grids)
5.8 kW
97.6 % euro
Hybrid
The verdict
SUN2000-6KTL-M1 leads on the differences that matter
The largest is rated ac power: 0.20 kW apart. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
8
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 19 parameters
What actually differs
Parameter
SUN2000-6KTL-M1
SE10K (Three Phase, Delta Grids)
Difference
Rated AC power
6.00 kW
5.80 kW
0.20 kW apart
Max DC voltage
1100 V
600 V
500 V apart
Max efficiency
98.6 %
98.0 %
0.6 pp more efficient
Max AC power
6.60 kW
5.80 kW
0.80 kW apart
Max PV power
9.00 kW
7.83 kW
1.17 kW apart
DC/AC ratio
1.50
1.35
0.15 more oversizing headroom
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
10.1 A
16.0 A
5.9 A apart
Weight
17.0 kg
16.4 kg
0.6 kg lighter
Dimensions
525x470x146 mm
540x315x260 mm
525x470x146 mm vs 540x315x260 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-6KTL-M1
SE10K (Three Phase, Delta Grids)
Difference
AC output
Rated AC power
6.00 kW
5.80 kW
0.20 kW apart
Max AC power
6.60 kW
5.80 kW
0.80 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
10.1 A
16.0 A
5.9 A apart
PV input
Max PV power
9.00 kW
7.83 kW
1.17 kW apart
DC/AC ratio
1.50
1.35
+0.15 for SUN2000-6KTL-M1
Max DC voltage
1100 V
600 V
500 V apart
MPPT voltage range
140-980 V
-
Not published by SolarEdge
Start voltage
200 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
11.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.7 %
97.6 %
Effectively the same
Max efficiency
98.6 %
98.0 %
+0.6 pp for SUN2000-6KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600 V ~ 980 V
-
Not published by SolarEdge
Max charge current
16 A
-
Not published by SolarEdge
Backup power
3.3 kW
-
Not published by SolarEdge
Physical
Weight
17.0 kg
16.4 kg
-0.6 kg for SE10K (Three Phase, Delta Grids)
Weight per kW
2.8 kg/kW
2.8 kg/kW
Same
Dimensions
525x470x146 mm
540x315x260 mm
525x470x146 mm vs 540x315x260 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
50 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by SolarEdge
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-M1 vs SolarEdge SE6000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-M1 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.