SUN2000-6KTL-M1 vs WIT 6K-HU 7 of 21 identical Swap Change inverters

Huawei SUN2000-6KTL-M1 vs Growatt WIT 6K-HU

Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
VS
Growatt WIT 6K-HU
Growatt
WIT 6K-HU
6 kW 97.0 % euro Hybrid
The verdict

SUN2000-6KTL-M1 leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
7 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 21 parameters
Parameter SUN2000-6KTL-M1 WIT 6K-HU Difference
European efficiency 97.7 % 97.0 % 0.7 pp more efficient
Max DC voltage 1100 V 1000 V 100 V apart
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max PV power 9.00 kW 9.60 kW 0.60 kW apart
Max charge current 16 A 290 A 274 A faster charging
Weight 17.0 kg 38.0 kg 21.0 kg lighter
Weight per kW 2.8 kg/kW 6.3 kg/kW 3.5 kg/kW lighter
DC/AC ratio 1.50 1.60 0.10 more oversizing headroom
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 140-980 V 150-850 V 140-980 V vs 150-850 V
Start voltage 200 V 180 V 20 V earlier start
Battery voltage 600 V ~ 980 V 40-60V (rated 51.2V) 600 V ~ 980 V vs 40-60V (rated 51.2V)
Dimensions 525x470x146 mm 698x475x240 mm 525x470x146 mm vs 698x475x240 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-6KTL-M1 WIT 6K-HU Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.60 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 10.1 A - Not published by Growatt
PV input
Max PV power 9.00 kW 9.60 kW 0.60 kW apart
DC/AC ratio 1.50 1.60 +0.10 for WIT 6K-HU
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 140-980 V 150-850 V 140-980 V vs 150-850 V
Start voltage 200 V 180 V -20 V for WIT 6K-HU
MPP trackers 2 - Not published by Growatt
Strings per tracker 1 - Not published by Growatt
Max input current per tracker 11.0 A - Not published by Growatt
Efficiency
European efficiency 97.7 % 97.0 % +0.7 pp for SUN2000-6KTL-M1
Max efficiency 98.6 % 97.6 % +1.0 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 40-60V (rated 51.2V) 600 V ~ 980 V vs 40-60V (rated 51.2V)
Max charge current 16 A 290 A +274 A for WIT 6K-HU
Backup power 3.3 kW - Not published by Growatt
Physical
Weight 17.0 kg 38.0 kg -21.0 kg for SUN2000-6KTL-M1
Weight per kW 2.8 kg/kW 6.3 kg/kW -3.5 kg/kW for SUN2000-6KTL-M1
Dimensions 525x470x146 mm 698x475x240 mm 525x470x146 mm vs 698x475x240 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural forced-air natural vs forced-air
Noise - 50 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Growatt
Ethernet Yes - Not published by Growatt
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-M1 vs SolarEdge SE6000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-M1 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.