Skip to main content
SUN2000-6KTL-M1 vs GW6000-ET-20 (ET G2) 10 of 26 identical Swap Change inverters

Huawei SUN2000-6KTL-M1 vs GoodWe GW6000-ET-20 (ET G2)

Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
VS
GoodWe GW6000-ET-20 (ET G2)
GoodWe
GW6000-ET-20 (ET G2)
6 kW Hybrid
The verdict

16 differences, and they point both ways

The largest is max dc voltage: 100 V apart. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter SUN2000-6KTL-M1 GW6000-ET-20 (ET G2) Difference
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 11.0 A 16.0 A 5.0 A more headroom
Max efficiency 98.6 % 98.0 % 0.6 pp more efficient
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Max PV power 9.00 kW 9.60 kW 0.60 kW apart
Max charge current 16 A 40 A 24 A faster charging
Weight 17.0 kg 23.0 kg 6.0 kg lighter
Weight per kW 2.8 kg/kW 3.8 kg/kW 1.0 kg/kW lighter
DC/AC ratio 1.50 1.60 0.10 more oversizing headroom
Max AC current 10.1 A 15.7 A 5.6 A apart
Start voltage 200 V 150 V 50 V earlier start
MPP trackers 2 3 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 140-980 V 120-850 V 140-980 V vs 120-850 V
Battery voltage 600 V ~ 980 V 150-720 V 600 V ~ 980 V vs 150-720 V
Dimensions 525x470x146 mm 460x496x221 mm 525x470x146 mm vs 460x496x221 mm
02

Full specification

Parameter SUN2000-6KTL-M1 GW6000-ET-20 (ET G2) Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 10.1 A 15.7 A 5.6 A apart
PV input
Max PV power 9.00 kW 9.60 kW 0.60 kW apart
DC/AC ratio 1.50 1.60 +0.10 for GW6000-ET-20 (ET G2)
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 140-980 V 120-850 V 140-980 V vs 120-850 V
Start voltage 200 V 150 V -50 V for GW6000-ET-20 (ET G2)
MPP trackers 2 3 +1 trackers for GW6000-ET-20 (ET G2)
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 16.0 A +5.0 A for GW6000-ET-20 (ET G2)
Efficiency
European efficiency 97.7 % - Not published by GoodWe
Max efficiency 98.6 % 98.0 % +0.6 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 150-720 V 600 V ~ 980 V vs 150-720 V
Max charge current 16 A 40 A +24 A for GW6000-ET-20 (ET G2)
Backup power 3.3 kW - Not published by GoodWe
Physical
Weight 17.0 kg 23.0 kg -6.0 kg for SUN2000-6KTL-M1
Weight per kW 2.8 kg/kW 3.8 kg/kW -1.0 kg/kW for SUN2000-6KTL-M1
Dimensions 525x470x146 mm 460x496x221 mm 525x470x146 mm vs 460x496x221 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by GoodWe
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-M1 vs SolarEdge SE6000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-M1 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.