SUN2000-6KTL-M1 vs Fronius Primo GEN24 6.0 Plus 7 of 27 identical Swap Change inverters

Huawei SUN2000-6KTL-M1 vs Fronius Primo GEN24 6.0 Plus

Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
VS
Fronius International
Fronius Primo GEN24 6.0 Plus
6 kW 97.1 % euro Hybrid
The verdict

20 differences, and they point both ways

The largest is european efficiency: 0.6 pp more efficient. 7 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 20 differences
How alike are they
7 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

20 of 27 parameters
Parameter SUN2000-6KTL-M1 Fronius Primo GEN24 6.0 Plus Difference
European efficiency 97.7 % 97.1 % 0.6 pp more efficient
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 11.0 A 22.0 A 11.0 A more headroom
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Max PV power 9.00 kW 6.20 kW 2.80 kW apart
DC/AC ratio 1.50 1.03 0.47 more oversizing headroom
Max charge current 16 A 22 A 6 A faster charging
Weight 17.0 kg 15.4 kg 1.6 kg lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.1 A 27.3 A 17.2 A apart
Start voltage 200 V 80 V 120 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
Weight per kW 2.8 kg/kW 2.6 kg/kW 0.3 kg/kW lighter
MPPT voltage range 140-980 V 65-530 V 140-980 V vs 65-530 V
Battery voltage 600 V ~ 980 V 150-455 V 600 V ~ 980 V vs 150-455 V
Strings per tracker 1 2 1 string apart
Dimensions 525x470x146 mm 530x474x165 mm 525x470x146 mm vs 530x474x165 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-6KTL-M1 Fronius Primo GEN24 6.0 Plus Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.1 A 27.3 A 17.2 A apart
PV input
Max PV power 9.00 kW 6.20 kW 2.80 kW apart
DC/AC ratio 1.50 1.03 +0.47 for SUN2000-6KTL-M1
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-980 V 65-530 V 140-980 V vs 65-530 V
Start voltage 200 V 80 V -120 V for Fronius Primo GEN24 6.0 Plus
MPP trackers 2 2 Same
Strings per tracker 1 2 1 string apart
Max input current per tracker 11.0 A 22.0 A +11.0 A for Fronius Primo GEN24 6.0 Plus
Efficiency
European efficiency 97.7 % 97.1 % +0.6 pp for SUN2000-6KTL-M1
Max efficiency 98.6 % 97.6 % +1.0 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 150-455 V 600 V ~ 980 V vs 150-455 V
Max charge current 16 A 22 A +6 A for Fronius Primo GEN24 6.0 Plus
Backup power 3.3 kW - Not published by Fronius International
Physical
Weight 17.0 kg 15.4 kg -1.6 kg for Fronius Primo GEN24 6.0 Plus
Weight per kW 2.8 kg/kW 2.6 kg/kW -0.3 kg/kW for Fronius Primo GEN24 6.0 Plus
Dimensions 525x470x146 mm 530x474x165 mm 525x470x146 mm vs 530x474x165 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural forced-air natural vs forced-air
Noise - 42 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by Fronius International
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-M1 vs SolarEdge SE6000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-M1 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.