Huawei SUN2000-6KTL-L1 vs Growatt SPA 6000TL3 BH-UP
VS
The verdict
SUN2000-6KTL-L1 leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
6
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 16 parameters
What actually differs
Parameter
SUN2000-6KTL-L1
SPA 6000TL3 BH-UP
Difference
European efficiency
97.8 %
97.3 %
0.5 pp more efficient
Max charge current
15 A
25 A
10 A faster charging
Weight
12.0 kg
30.0 kg
18.0 kg lighter
Weight per kW
2.0 kg/kW
5.0 kg/kW
3.0 kg/kW lighter
Max efficiency
98.4 %
98.0 %
0.4 pp more efficient
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
27.3 A
9.1 A
18.2 A apart
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
100-550 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 100-550 V
Dimensions
365x365x156 mm
453x505x198 mm
365x365x156 mm vs 453x505x198 mm
02
Full specification
Parameter
SUN2000-6KTL-L1
SPA 6000TL3 BH-UP
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.00 kW
6.00 kW
Same
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
27.3 A
9.1 A
18.2 A apart
PV input
Max PV power
9.00 kW
-
Not published by Growatt
DC/AC ratio
1.50
-
Not published by Growatt
Max DC voltage
600 V
-
Not published by Growatt
MPPT voltage range
90-560 V
-
Not published by Growatt
Start voltage
100 V
-
Not published by Growatt
MPP trackers
2
-
Not published by Growatt
Strings per tracker
1
-
Not published by Growatt
Max input current per tracker
12.5 A
-
Not published by Growatt
Efficiency
European efficiency
97.8 %
97.3 %
+0.5 pp for SUN2000-6KTL-L1
Max efficiency
98.4 %
98.0 %
+0.4 pp for SUN2000-6KTL-L1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
100-550 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 100-550 V
Max charge current
15 A
25 A
+10 A for SPA 6000TL3 BH-UP
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.0 kg
30.0 kg
-18.0 kg for SUN2000-6KTL-L1
Weight per kW
2.0 kg/kW
5.0 kg/kW
-3.0 kg/kW for SUN2000-6KTL-L1
Dimensions
365x365x156 mm
453x505x198 mm
365x365x156 mm vs 453x505x198 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Growatt
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
5 yrs
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-L1 vs SolarEdge SE6000H
6 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-L1 vs Growatt MOD 6000TL3-HU
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-L1 vs Huawei SUN2000-6KTL-M1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

