Huawei SUN2000-6KTL-L1 vs Ginlong Solis S6-EH3P6K-H-EU
VS
The verdict
16 differences, and they point both ways
The largest is max dc voltage: 400 V apart. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
7
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 23 parameters
What actually differs
Parameter
SUN2000-6KTL-L1
S6-EH3P6K-H-EU
Difference
Max DC voltage
600 V
1000 V
400 V apart
Max input current per tracker
12.5 A
16.0 A
3.5 A more headroom
Max efficiency
98.4 %
97.0 %
1.4 pp more efficient
Max PV power
9.00 kW
12.00 kW
3.00 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Max charge current
15 A
50 A
35 A faster charging
Weight
12.0 kg
27.6 kg
15.6 kg lighter
Weight per kW
2.0 kg/kW
4.6 kg/kW
2.6 kg/kW lighter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
27.3 A
9.1 A
18.2 A apart
Start voltage
100 V
160 V
60 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
90-560 V
200-850 V
90-560 V vs 200-850 V
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
120-600 V (note: supports max battery voltage up to 700 V)
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 120-600 V (note: supports max battery voltage up to 700 V)
Dimensions
365x365x156 mm
500x600x210 mm
365x365x156 mm vs 500x600x210 mm
02
Full specification
Parameter
SUN2000-6KTL-L1
S6-EH3P6K-H-EU
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.00 kW
6.00 kW
Same
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
27.3 A
9.1 A
18.2 A apart
PV input
Max PV power
9.00 kW
12.00 kW
3.00 kW apart
DC/AC ratio
1.50
2.00
+0.50 for S6-EH3P6K-H-EU
Max DC voltage
600 V
1000 V
400 V apart
MPPT voltage range
90-560 V
200-850 V
90-560 V vs 200-850 V
Start voltage
100 V
160 V
-60 V for SUN2000-6KTL-L1
MPP trackers
2
-
Not published by Ginlong Solis
Strings per tracker
1
1
Same
Max input current per tracker
12.5 A
16.0 A
+3.5 A for S6-EH3P6K-H-EU
Efficiency
European efficiency
97.8 %
-
Not published by Ginlong Solis
Max efficiency
98.4 %
97.0 %
+1.4 pp for SUN2000-6KTL-L1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
120-600 V (note: supports max battery voltage up to 700 V)
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 120-600 V (note: supports max battery voltage up to 700 V)
Max charge current
15 A
50 A
+35 A for S6-EH3P6K-H-EU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.0 kg
27.6 kg
-15.6 kg for SUN2000-6KTL-L1
Weight per kW
2.0 kg/kW
4.6 kg/kW
-2.6 kg/kW for SUN2000-6KTL-L1
Dimensions
365x365x156 mm
500x600x210 mm
365x365x156 mm vs 500x600x210 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
47 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-L1 vs SolarEdge SE6000H
6 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-L1 vs Growatt MOD 6000TL3-HU
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-L1 vs Huawei SUN2000-6KTL-M1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.