Huawei SUN2000-6KTL-L1 vs Deye SUN-6K-SG04LP3-EU
VS
The verdict
SUN2000-6KTL-L1 leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 5 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
5
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 20 parameters
What actually differs
Parameter
SUN2000-6KTL-L1
SUN-6K-SG04LP3-EU
Difference
European efficiency
97.8 %
97.0 %
0.8 pp more efficient
Max DC voltage
600 V
800 V
200 V apart
Max efficiency
98.4 %
97.6 %
0.8 pp more efficient
Max AC power
6.00 kW
6.60 kW
0.60 kW apart
Max PV power
9.00 kW
7.80 kW
1.20 kW apart
Weight
12.0 kg
33.6 kg
21.6 kg lighter
Weight per kW
2.0 kg/kW
5.6 kg/kW
3.6 kg/kW lighter
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Start voltage
100 V
160 V
60 V earlier start
MPPT voltage range
90-560 V
200-650 V
90-560 V vs 200-650 V
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
40-60 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 40-60 V
Dimensions
365x365x156 mm
699x422x279 mm
365x365x156 mm vs 699x422x279 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-6KTL-L1
SUN-6K-SG04LP3-EU
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.00 kW
6.60 kW
0.60 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
27.3 A
-
Not published by Deye
PV input
Max PV power
9.00 kW
7.80 kW
1.20 kW apart
DC/AC ratio
1.50
1.30
+0.20 for SUN2000-6KTL-L1
Max DC voltage
600 V
800 V
200 V apart
MPPT voltage range
90-560 V
200-650 V
90-560 V vs 200-650 V
Start voltage
100 V
160 V
-60 V for SUN2000-6KTL-L1
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Deye
Max input current per tracker
12.5 A
-
Not published by Deye
Efficiency
European efficiency
97.8 %
97.0 %
+0.8 pp for SUN2000-6KTL-L1
Max efficiency
98.4 %
97.6 %
+0.8 pp for SUN2000-6KTL-L1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
40-60 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh) vs 40-60 V
Max charge current
15 A
-
Not published by Deye
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.0 kg
33.6 kg
-21.6 kg for SUN2000-6KTL-L1
Weight per kW
2.0 kg/kW
5.6 kg/kW
-3.6 kg/kW for SUN2000-6KTL-L1
Dimensions
365x365x156 mm
699x422x279 mm
365x365x156 mm vs 699x422x279 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
45 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Deye
Ethernet
Yes
-
Not published by Deye
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
-
Not published by Deye
Warranty
Warranty
-
5 yrs
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-6KTL-L1 vs SolarEdge SE6000H
6 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-6KTL-L1 vs Growatt MOD 6000TL3-HU
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-L1 vs Huawei SUN2000-6KTL-M1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.