Skip to main content
SUN2000-50KTL-M0 vs SOFAR 50000TL 7 of 19 identical Swap Change inverters

Huawei SUN2000-50KTL-M0 vs SOFAR 50000TL

Huawei
SUN2000-50KTL-M0
50 kW 98.5 % euro Grid-tie
VS
Sofar Solar
SOFAR 50000TL
50 kW 98.3 % euro Grid-tie
The verdict

12 differences, and they point both ways

The largest is max dc voltage: 100 V apart. 7 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 19 parameters
Parameter SUN2000-50KTL-M0 SOFAR 50000TL Difference
Max DC voltage 1100 V 1000 V 100 V apart
MPP trackers 6 3 3 trackers more
Max input current per tracker 22.0 A 40.0 A 18.0 A more headroom
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Weight 74.0 kg 68.0 kg 6.0 kg lighter
European efficiency 98.5 % 98.3 % 0.2 pp more efficient
Start voltage 200 V 350 V 150 V earlier start
Max efficiency 98.7 % 98.5 % 0.2 pp more efficient
MPPT voltage range 200-1000 V 250-950 V 200-1000 V vs 250-950 V
Max AC current 79.4 A 80.0 A 0.6 A apart
Dimensions 555x1075x300 mm 737x713x297 mm 555x1075x300 mm vs 737x713x297 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-50KTL-M0 SOFAR 50000TL Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.00 kW 50.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 79.4 A 80.0 A 0.6 A apart
PV input
Max PV power - 66.50 kW Not published by Huawei
DC/AC ratio - 1.33 Not published by Huawei
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 200-1000 V 250-950 V 200-1000 V vs 250-950 V
Start voltage 200 V 350 V -150 V for SUN2000-50KTL-M0
MPP trackers 6 3 +3 trackers for SUN2000-50KTL-M0
Strings per tracker 2 - Not published by Sofar Solar
Max input current per tracker 22.0 A 40.0 A +18.0 A for SOFAR 50000TL
Efficiency
European efficiency 98.5 % 98.3 % +0.2 pp for SUN2000-50KTL-M0
Max efficiency 98.7 % 98.5 % +0.2 pp for SUN2000-50KTL-M0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 74.0 kg 68.0 kg -6.0 kg for SOFAR 50000TL
Weight per kW 1.5 kg/kW 1.4 kg/kW Effectively the same
Dimensions 555x1075x300 mm 737x713x297 mm 555x1075x300 mm vs 737x713x297 mm
Ingress protection IP65 IP65 Same
Cooling natural forced-air natural vs forced-air
Noise - 60 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Huawei
Ethernet - Yes Not published by Huawei
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Huawei SUN2000-50KTL-M0 vs Huawei SUN2000-50KTL-JPM0
4 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Huawei SUN2000-50KTL-M0 vs Solis-50K-HV
6 differences, the largest is mpp trackers
Same type, similar size
Growatt
Huawei SUN2000-50KTL-M0 vs Growatt MAX 50KTL3 LV
7 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.