Huawei SUN2000-50KTL-JPM0 vs Huawei SUN2000-50KTL-ZHM3
VS
The verdict
ZHM3 leads on the differences that matter
The largest is max input current per tracker: 8.0 A more headroom. 7 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
7
of 17 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 17 parameters
What actually differs
Parameter
JPM0
ZHM3
Difference
Max input current per tracker
22.0 A
30.0 A
8.0 A more headroom
Max AC power
55.50 kW
50.00 kW
5.50 kW apart
MPP trackers
6
4
2 trackers more
Weight
71.0 kg
49.0 kg
22.0 kg lighter
Max efficiency
98.9 %
98.5 %
0.4 pp more efficient
Weight per kW
1.4 kg/kW
1.0 kg/kW
0.4 kg/kW lighter
Max AC current
68.8 A
84.0 A
15.2 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
Dimensions
555x1075x300 mm
640x530x270 mm
555x1075x300 mm vs 640x530x270 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
JPM0
ZHM3
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.50 kW
50.00 kW
5.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
380 V
Not published by Huawei
Max AC current
68.8 A
84.0 A
15.2 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
200 V
200 V
Same
MPP trackers
6
4
+2 trackers for JPM0
Strings per tracker
2
2
Same
Max input current per tracker
22.0 A
30.0 A
+8.0 A for ZHM3
Efficiency
European efficiency
98.6 %
-
Not published by Huawei
Max efficiency
98.9 %
98.5 %
+0.4 pp for JPM0
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
71.0 kg
49.0 kg
-22.0 kg for ZHM3
Weight per kW
1.4 kg/kW
1.0 kg/kW
-0.4 kg/kW for ZHM3
Dimensions
555x1075x300 mm
640x530x270 mm
555x1075x300 mm vs 640x530x270 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Huawei
Ethernet
-
Yes
Not published by Huawei
Arc fault protection
-
Yes
Not published by Huawei
Integrated DC switch
-
Yes
Not published by Huawei
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Huawei SUN2000-50KTL-JPM0 vs Huawei SUN2000-50KTL-M0
4 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Huawei SUN2000-50KTL-JPM0 vs Solis-50K-HV
6 differences, the largest is max ac power
Same type, similar size
Growatt
Huawei SUN2000-50KTL-JPM0 vs Growatt MAX 50KTL3 LV
8 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.