Skip to main content
SUN2000-50KTL-JPM0 vs S5-GC50K 6 of 17 identical Swap Change inverters

Huawei SUN2000-50KTL-JPM0 vs Ginlong Solis S5-GC50K

Huawei SUN2000-50KTL-JPM0
Huawei
SUN2000-50KTL-JPM0
50 kW 98.6 % euro Grid-tie
VS
Ginlong Solis S5-GC50K
Ginlong Solis
S5-GC50K
50 kW 98.3 % euro Grid-tie
The verdict

S5-GC50K leads on the differences that matter

The largest is max input current per tracker: 10.0 A more headroom. 6 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
6 of 17 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 17 parameters
Parameter SUN2000-50KTL-JPM0 S5-GC50K Difference
Max input current per tracker 22.0 A 32.0 A 10.0 A more headroom
Max AC power 55.50 kW 55.00 kW 0.50 kW apart
Weight 71.0 kg 53.7 kg 17.3 kg lighter
European efficiency 98.6 % 98.3 % 0.3 pp more efficient
Max AC current 68.8 A 83.6 A 14.8 A apart
Weight per kW 1.4 kg/kW 1.1 kg/kW 0.3 kg/kW lighter
Max efficiency 98.9 % 98.7 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Dimensions 555x1075x300 mm 578x691x338 mm 555x1075x300 mm vs 578x691x338 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-50KTL-JPM0 S5-GC50K Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.50 kW 55.00 kW 0.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage - 400 V Not published by Huawei
Max AC current 68.8 A 83.6 A 14.8 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 200 V 195 V Effectively the same
MPP trackers 6 - Not published by Ginlong Solis
Strings per tracker 2 2 Same
Max input current per tracker 22.0 A 32.0 A +10.0 A for S5-GC50K
Efficiency
European efficiency 98.6 % 98.3 % +0.3 pp for SUN2000-50KTL-JPM0
Max efficiency 98.9 % 98.7 % +0.2 pp for SUN2000-50KTL-JPM0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 71.0 kg 53.7 kg -17.3 kg for S5-GC50K
Weight per kW 1.4 kg/kW 1.1 kg/kW -0.3 kg/kW for S5-GC50K
Dimensions 555x1075x300 mm 578x691x338 mm 555x1075x300 mm vs 578x691x338 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural forced-air natural vs forced-air
Noise - 55 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Huawei
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Huawei
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Huawei SUN2000-50KTL-JPM0 vs Huawei SUN2000-50KTL-M0
4 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Huawei SUN2000-50KTL-JPM0 vs Solis-50K-HV
6 differences, the largest is max ac power
Same type, similar size
Growatt
Huawei SUN2000-50KTL-JPM0 vs Growatt MAX 50KTL3 LV
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.