Huawei SUN2000-40KTL-M3 vs GoodWe GW40K-SDT-C30
VS
The verdict
GW40K-SDT-C30 leads on the differences that matter
The largest is max input current per tracker: 16.0 A more headroom. 9 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
9
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 19 parameters
What actually differs
Parameter
SUN2000-40KTL-M3
GW40K-SDT-C30
Difference
Max input current per tracker
26.0 A
42.0 A
16.0 A more headroom
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Weight
43.0 kg
28.0 kg
15.0 kg lighter
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
63.8 A
66.7 A
2.9 A apart
Start voltage
200 V
160 V
40 V earlier start
Weight per kW
1.1 kg/kW
0.7 kg/kW
0.4 kg/kW lighter
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Dimensions
530x640x270 mm
483x585x230 mm
530x640x270 mm vs 483x585x230 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-40KTL-M3
GW40K-SDT-C30
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
40.00 kW
44.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
63.8 A
66.7 A
2.9 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Start voltage
200 V
160 V
-40 V for GW40K-SDT-C30
MPP trackers
4
-
Not published by GoodWe
Strings per tracker
2
-
Not published by GoodWe
Max input current per tracker
26.0 A
42.0 A
+16.0 A for GW40K-SDT-C30
Efficiency
European efficiency
98.4 %
-
Not published by GoodWe
Max efficiency
98.7 %
98.7 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
43.0 kg
28.0 kg
-15.0 kg for GW40K-SDT-C30
Weight per kW
1.1 kg/kW
0.7 kg/kW
-0.4 kg/kW for GW40K-SDT-C30
Dimensions
530x640x270 mm
483x585x230 mm
530x640x270 mm vs 483x585x230 mm
Ingress protection
IP66
IP66
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
29 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Huawei
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Huawei SUN2000-40KTL-M3 vs Growatt MID 40KTL3-X
7 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Huawei SUN2000-40KTL-M3 vs Solis-40K
6 differences, the largest is max ac power
Same type, similar size
Sungrow
Huawei SUN2000-40KTL-M3 vs Sungrow SG40CX-P2
8 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.