Skip to main content
SUN2000-3K-LB0 vs MOD 3000TL3-HU 10 of 26 identical Swap Change inverters

Huawei SUN2000-3K-LB0 vs Growatt MOD 3000TL3-HU

Huawei SUN2000-3K-LB0
Huawei
SUN2000-3K-LB0
3 kW 96.6 % euro Hybrid
VS
Growatt MOD 3000TL3-HU
Growatt
MOD 3000TL3-HU
3 kW 97.8 % euro Hybrid
The verdict

MOD 3000TL3-HU leads on the differences that matter

The largest is european efficiency: 1.2 pp more efficient. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter SUN2000-3K-LB0 MOD 3000TL3-HU Difference
European efficiency 96.6 % 97.8 % 1.2 pp more efficient
Max DC voltage 600 V 1000 V 400 V apart
Max input current per tracker 16.0 A 20.0 A 4.0 A more headroom
Max PV power 4.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 1.50 2.00 0.50 more oversizing headroom
Max charge current 16 A 25 A 8 A faster charging
Weight 15.0 kg 19.0 kg 4.0 kg lighter
Weight per kW 5.0 kg/kW 6.3 kg/kW 1.3 kg/kW lighter
Max efficiency 97.8 % 98.3 % 0.5 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 15.0 A 5.0 A 10.0 A apart
Start voltage 50 V 180 V 130 V earlier start
MPPT voltage range 40-560 V 140-1000 V 40-560 V vs 140-1000 V
Battery voltage 350-560 Vdc 600-980 V 350-560 Vdc vs 600-980 V
Dimensions 425x376x150 mm 468x408x202 mm 425x376x150 mm vs 468x408x202 mm
02

Full specification

Parameter SUN2000-3K-LB0 MOD 3000TL3-HU Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.30 kW 3.30 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 15.0 A 5.0 A 10.0 A apart
PV input
Max PV power 4.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 1.50 2.00 +0.50 for MOD 3000TL3-HU
Max DC voltage 600 V 1000 V 400 V apart
MPPT voltage range 40-560 V 140-1000 V 40-560 V vs 140-1000 V
Start voltage 50 V 180 V -130 V for SUN2000-3K-LB0
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 20.0 A +4.0 A for MOD 3000TL3-HU
Efficiency
European efficiency 96.6 % 97.8 % +1.2 pp for MOD 3000TL3-HU
Max efficiency 97.8 % 98.3 % +0.5 pp for MOD 3000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 350-560 Vdc 600-980 V 350-560 Vdc vs 600-980 V
Max charge current 16 A 25 A +8 A for MOD 3000TL3-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 15.0 kg 19.0 kg -4.0 kg for SUN2000-3K-LB0
Weight per kW 5.0 kg/kW 6.3 kg/kW -1.3 kg/kW for SUN2000-3K-LB0
Dimensions 425x376x150 mm 468x408x202 mm 425x376x150 mm vs 468x408x202 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - 29 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by Huawei
Warranty
Warranty - 10 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000-3K-LB0 vs SolarEdge SE3000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-3K-LB0 vs Growatt SPM 3000TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Huawei
Huawei SUN2000-3K-LB0 vs Huawei SUN2000L-3KTL
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt MOD 3000TL3-XH
9 differences, the largest is warranty
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.