Huawei SUN2000-20KTL-M3 vs Sungrow SG20KTL-M
VS
The verdict
13 differences, and they point both ways
The largest is max dc voltage: 350 V apart. 5 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
5
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 18 parameters
What actually differs
Parameter
SUN2000-20KTL-M3
SG20KTL-M
Difference
Max DC voltage
750 V
1100 V
350 V apart
Max input current per tracker
26.0 A
22.0 A
4.0 A more headroom
Max efficiency
97.6 %
98.6 %
1.0 pp more efficient
MPP trackers
4
2
2 trackers more
Weight
43.0 kg
24.0 kg
19.0 kg lighter
Weight per kW
2.1 kg/kW
1.2 kg/kW
0.9 kg/kW lighter
Nominal AC voltage
202 V
400 V
198 V apart
Max AC current
57.2 A
31.9 A
25.3 A apart
Start voltage
200 V
250 V
50 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
200-750 V
200-1000 V
200-750 V vs 200-1000 V
Dimensions
530x681x270 mm
485x370x210 mm
530x681x270 mm vs 485x370x210 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-20KTL-M3
SG20KTL-M
Difference
AC output
Rated AC power
20.00 kW
20.00 kW
Same
Max AC power
20.00 kW
20.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
202 V
400 V
198 V apart
Max AC current
57.2 A
31.9 A
25.3 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
750 V
1100 V
350 V apart
MPPT voltage range
200-750 V
200-1000 V
200-750 V vs 200-1000 V
Start voltage
200 V
250 V
-50 V for SUN2000-20KTL-M3
MPP trackers
4
2
+2 trackers for SUN2000-20KTL-M3
Strings per tracker
2
2
Same
Max input current per tracker
26.0 A
22.0 A
+4.0 A for SUN2000-20KTL-M3
Efficiency
European efficiency
-
98.3 %
Not published by Huawei
Max efficiency
97.6 %
98.6 %
+1.0 pp for SG20KTL-M
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
43.0 kg
24.0 kg
-19.0 kg for SG20KTL-M
Weight per kW
2.1 kg/kW
1.2 kg/kW
-0.9 kg/kW for SG20KTL-M
Dimensions
530x681x270 mm
485x370x210 mm
530x681x270 mm vs 485x370x210 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
50 dB
-
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
-
Yes
Not published by Huawei
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Huawei SUN2000-20KTL-M3 vs Growatt MID 20KTL3-X
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Huawei SUN2000-20KTL-M3 vs Fronius Verto 20.0
12 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-20KTL-M3 vs Huawei SUN2000-20KTL-M2
12 differences, the largest is max dc voltage
Same type, similar size
Huawei
Sungrow SG20KTL-M vs Huawei SUN2000-20KTL-M0
8 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.