Skip to main content
SUN2000-15K-MB0 vs MID 15KTL3-XH 14 of 26 identical Swap Change inverters

Huawei SUN2000-15K-MB0 vs Growatt MID 15KTL3-XH

Huawei SUN2000-15K-MB0
Huawei
SUN2000-15K-MB0
15 kW 98.0 % euro Hybrid
VS
Growatt MID 15KTL3-XH
Growatt
MID 15KTL3-XH
15 kW 98.5 % euro Hybrid
The verdict

MID 15KTL3-XH leads on the differences that matter

The largest is european efficiency: 0.5 pp more efficient. 14 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
14 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 26 parameters
Parameter SUN2000-15K-MB0 MID 15KTL3-XH Difference
European efficiency 98.0 % 98.5 % 0.5 pp more efficient
Max input current per tracker 30.0 A 32.0 A 2.0 A more headroom
Max AC power 16.50 kW 15.00 kW 1.50 kW apart
Max PV power 22.50 kW 30.00 kW 7.50 kW apart
DC/AC ratio 1.50 2.00 0.50 more oversizing headroom
Weight 21.0 kg 31.0 kg 10.0 kg lighter
Weight per kW 1.4 kg/kW 2.1 kg/kW 0.7 kg/kW lighter
Max efficiency 98.4 % 98.8 % 0.3 pp more efficient
Max charge current 26 A 25 A 1 A faster charging
MPPT voltage range 200-1000 V 160-1000 V 200-1000 V vs 160-1000 V
Battery voltage 600 V ~ 980 V 600-980 V 600 V ~ 980 V vs 600-980 V
Dimensions 460x546x242 mm 435x580x230 mm 460x546x242 mm vs 435x580x230 mm
02

Full specification

Parameter SUN2000-15K-MB0 MID 15KTL3-XH Difference
AC output
Rated AC power 15.00 kW 15.00 kW Same
Max AC power 16.50 kW 15.00 kW 1.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 25.2 A 25.0 A Effectively the same
PV input
Max PV power 22.50 kW 30.00 kW 7.50 kW apart
DC/AC ratio 1.50 2.00 +0.50 for MID 15KTL3-XH
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 160-1000 V 200-1000 V vs 160-1000 V
Start voltage 200 V 200 V Same
MPP trackers 2 - Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 30.0 A 32.0 A +2.0 A for MID 15KTL3-XH
Efficiency
European efficiency 98.0 % 98.5 % +0.5 pp for MID 15KTL3-XH
Max efficiency 98.4 % 98.8 % +0.3 pp for MID 15KTL3-XH
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 600-980 V 600 V ~ 980 V vs 600-980 V
Max charge current 26 A 25 A +1 A for SUN2000-15K-MB0
Backup power - - Neither datasheet publishes this
Physical
Weight 21.0 kg 31.0 kg -10.0 kg for SUN2000-15K-MB0
Weight per kW 1.4 kg/kW 2.1 kg/kW -0.7 kg/kW for SUN2000-15K-MB0
Dimensions 460x546x242 mm 435x580x230 mm 460x546x242 mm vs 435x580x230 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Huawei SUN2000-15K-MB0 vs Growatt MOD 15KTL3-HU
15 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Huawei SUN2000-15K-MB0 vs Sofar Solar HYD 15KTL-3PH
12 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Huawei SUN2000-15K-MB0 vs Sungrow SH15T
16 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.