Skip to main content
SUN2000-150K-MG0-ZH vs MAX 150KTL3-X LV 11 of 19 identical Swap Change inverters

Huawei SUN2000-150K-MG0-ZH vs Growatt MAX 150KTL3-X LV

Huawei SUN2000-150K-MG0-ZH
Huawei
SUN2000-150K-MG0-ZH
150 kW Grid-tie
VS
Growatt MAX 150KTL3-X LV
Growatt
MAX 150KTL3-X LV
150 kW 98.4 % euro Grid-tie
The verdict

MAX 150KTL3-X LV leads on the differences that matter

The largest is mpp trackers: 3 trackers more. 11 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
11 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 19 parameters
Parameter SUN2000-150K-MG0-ZH MAX 150KTL3-X LV Difference
MPP trackers 7 10 3 trackers more
Max input current per tracker 48.0 A 45.0 A 3.0 A more headroom
Max AC power 165.00 kW 150.00 kW 15.00 kW apart
Weight 102.0 kg 93.0 kg 9.0 kg lighter
Nominal AC voltage 380 V 400 V 20 V apart
Max AC current 253.2 A 250.7 A 2.5 A apart
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Dimensions 710x1000x395 mm 640x1075x367 mm 710x1000x395 mm vs 640x1075x367 mm
02

Full specification

Parameter SUN2000-150K-MG0-ZH MAX 150KTL3-X LV Difference
AC output
Rated AC power 150.00 kW 150.00 kW Same
Max AC power 165.00 kW 150.00 kW 15.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 380 V 400 V 20 V apart
Max AC current 253.2 A 250.7 A 2.5 A apart
PV input
Max PV power - 225.00 kW Not published by Huawei
DC/AC ratio - 1.50 Not published by Huawei
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 200 V 195 V Effectively the same
MPP trackers 7 10 +3 trackers for MAX 150KTL3-X LV
Strings per tracker 3 - Not published by Growatt
Max input current per tracker 48.0 A 45.0 A +3.0 A for SUN2000-150K-MG0-ZH
Efficiency
European efficiency - 98.4 % Not published by Huawei
Max efficiency 98.8 % 98.8 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 102.0 kg 93.0 kg -9.0 kg for MAX 150KTL3-X LV
Weight per kW 0.7 kg/kW 0.6 kg/kW Effectively the same
Dimensions 710x1000x395 mm 640x1075x367 mm 710x1000x395 mm vs 640x1075x367 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SMA Solar
Huawei SUN2000-150K-MG0-ZH vs SMA Solar Sunny Highpower PEAK3 SHP 150-21
9 differences, the largest is mpp trackers
Same type, similar size
SMA Solar
Huawei SUN2000-150K-MG0-ZH vs SMA Solar Sunny Highpower Storage SHPS 150-21
7 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Huawei SUN2000-150K-MG0-ZH vs Ginlong Solis S6-GC3P150K07-NV-ND
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MAX 150KTL3-X LV vs Sungrow SG150CX
7 differences, the largest is mpp trackers
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.