Skip to main content
SUN2000-12KTL-M1 (High current version) vs GW12K-ET-20 (ET G2) 11 of 26 identical Swap Change inverters

Huawei SUN2000-12KTL-M1 (High current version) vs GoodWe GW12K-ET-20 (ET G2)

Huawei SUN2000-12KTL-M1 (High current version)
Huawei
SUN2000-12KTL-M1 (High current version)
12 kW 98.2 % euro Hybrid
VS
GoodWe GW12K-ET-20 (ET G2)
GoodWe
GW12K-ET-20 (ET G2)
12 kW Hybrid
The verdict

GW12K-ET-20 (ET G2) leads on the differences that matter

The largest is max dc voltage: 100 V apart. 11 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
11 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 26 parameters
Parameter SUN2000-12KTL-M1 (High current version) GW12K-ET-20 (ET G2) Difference
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 13.5 A 16.0 A 2.5 A more headroom
Max PV power 18.00 kW 19.20 kW 1.20 kW apart
Max charge current 17 A 40 A 23 A faster charging
Weight 17.0 kg 25.0 kg 8.0 kg lighter
Weight per kW 1.4 kg/kW 2.1 kg/kW 0.7 kg/kW lighter
Max efficiency 98.6 % 98.2 % 0.4 pp more efficient
DC/AC ratio 1.50 1.60 0.10 more oversizing headroom
Max AC current 18.4 A 26.1 A 7.7 A apart
Start voltage 200 V 150 V 50 V earlier start
MPP trackers 2 3 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 140-980 V 120-850 V 140-980 V vs 120-850 V
Battery voltage 600 V ~ 980 V 150-720 V 600 V ~ 980 V vs 150-720 V
Dimensions 470x525x166 mm 460x496x221 mm 470x525x166 mm vs 460x496x221 mm
02

Full specification

Parameter SUN2000-12KTL-M1 (High current version) GW12K-ET-20 (ET G2) Difference
AC output
Rated AC power 12.00 kW 12.00 kW Same
Max AC power 12.00 kW 12.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 18.4 A 26.1 A 7.7 A apart
PV input
Max PV power 18.00 kW 19.20 kW 1.20 kW apart
DC/AC ratio 1.50 1.60 +0.10 for GW12K-ET-20 (ET G2)
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 140-980 V 120-850 V 140-980 V vs 120-850 V
Start voltage 200 V 150 V -50 V for GW12K-ET-20 (ET G2)
MPP trackers 2 3 +1 trackers for GW12K-ET-20 (ET G2)
Strings per tracker 1 1 Same
Max input current per tracker 13.5 A 16.0 A +2.5 A for GW12K-ET-20 (ET G2)
Efficiency
European efficiency 98.2 % - Not published by GoodWe
Max efficiency 98.6 % 98.2 % +0.4 pp for SUN2000-12KTL-M1 (High current version)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 150-720 V 600 V ~ 980 V vs 150-720 V
Max charge current 17 A 40 A +23 A for GW12K-ET-20 (ET G2)
Backup power 3.3 kW - Not published by GoodWe
Physical
Weight 17.0 kg 25.0 kg -8.0 kg for SUN2000-12KTL-M1 (High current version)
Weight per kW 1.4 kg/kW 2.1 kg/kW -0.7 kg/kW for SUN2000-12KTL-M1 (High current version)
Dimensions 470x525x166 mm 460x496x221 mm 470x525x166 mm vs 460x496x221 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by GoodWe
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Huawei SUN2000-12KTL-M1 (High current version) vs Growatt MID 12KTL3-XH
14 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-12KTL-M1 (High current version) vs Huawei SUN5000-12K-MAP0
13 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-12KTL-M1 (High current version) vs Huawei SUN2000-12K-MAP0
13 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.