Huawei SUN2000-12KTL-M1 (High current version) vs Deye SUN-12K-SG01LP3

Huawei SUN2000-12KTL-M1 (High current version)
Huawei
SUN2000-12KTL-M1 (High current version)
12 kW 98.2 % euro Hybrid
VS
Deye
SUN-12K-SG01LP3
12 kW 97.0 % euro Hybrid
The verdict

SUN2000-12KTL-M1 (High current version) leads on the differences that matter

The largest is european efficiency: 1.2 pp more efficient. 7 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
7 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 22 parameters
Parameter SUN2000-12KTL-M1 (High current version) SUN-12K-SG01LP3 Difference
European efficiency 98.2 % 97.0 % 1.2 pp more efficient
Max DC voltage 1100 V 800 V 300 V apart
Max input current per tracker 13.5 A 25.0 A 11.5 A more headroom
Max efficiency 98.6 % 97.6 % 1.0 pp more efficient
Max AC power 12.00 kW 13.20 kW 1.20 kW apart
Max PV power 18.00 kW 15.60 kW 2.40 kW apart
Weight 17.0 kg 45.0 kg 28.0 kg lighter
Weight per kW 1.4 kg/kW 3.8 kg/kW 2.3 kg/kW lighter
DC/AC ratio 1.50 1.30 0.20 more oversizing headroom
Start voltage 200 V 160 V 40 V earlier start
MPPT voltage range 140-980 V 140-700 V 140-980 V vs 140-700 V
Battery voltage 600 V ~ 980 V 40-60 V 600 V ~ 980 V vs 40-60 V
Max AC current 18.4 A 19.1 A 0.7 A apart
Dimensions 470x525x166 mm 656x420x281 mm 470x525x166 mm vs 656x420x281 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-12KTL-M1 (High current version) SUN-12K-SG01LP3 Difference
AC output
Rated AC power 12.00 kW 12.00 kW Same
Max AC power 12.00 kW 13.20 kW 1.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 18.4 A 19.1 A 0.7 A apart
PV input
Max PV power 18.00 kW 15.60 kW 2.40 kW apart
DC/AC ratio 1.50 1.30 +0.20 for SUN2000-12KTL-M1 (High current version)
Max DC voltage 1100 V 800 V 300 V apart
MPPT voltage range 140-980 V 140-700 V 140-980 V vs 140-700 V
Start voltage 200 V 160 V -40 V for SUN-12K-SG01LP3
MPP trackers 2 2 Same
Strings per tracker 1 - Not published by Deye
Max input current per tracker 13.5 A 25.0 A +11.5 A for SUN-12K-SG01LP3
Efficiency
European efficiency 98.2 % 97.0 % +1.2 pp for SUN2000-12KTL-M1 (High current version)
Max efficiency 98.6 % 97.6 % +1.0 pp for SUN2000-12KTL-M1 (High current version)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 40-60 V 600 V ~ 980 V vs 40-60 V
Max charge current 17 A - Not published by Deye
Backup power 3.3 kW - Not published by Deye
Physical
Weight 17.0 kg 45.0 kg -28.0 kg for SUN2000-12KTL-M1 (High current version)
Weight per kW 1.4 kg/kW 3.8 kg/kW -2.3 kg/kW for SUN2000-12KTL-M1 (High current version)
Dimensions 470x525x166 mm 656x420x281 mm 470x525x166 mm vs 656x420x281 mm
Ingress protection IP65 IP65 Same
Cooling natural forced-air natural vs forced-air
Noise - 30 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Deye
Ethernet Yes - Not published by Deye
Arc fault protection Yes - Not published by Deye
Integrated DC switch Yes - Not published by Deye
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Huawei SUN2000-12KTL-M1 (High current version) vs Growatt MID 12KTL3-XH
14 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-12KTL-M1 (High current version) vs Huawei SUN5000-12K-MAP0
13 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-12KTL-M1 (High current version) vs Huawei SUN2000-12K-MAP0
13 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.