Skip to main content
SUN2000-125KTL-JPH0 vs SOFAR 125KTLX-G4-A 8 of 18 identical Swap Change inverters

Huawei SUN2000-125KTL-JPH0 vs SOFAR 125KTLX-G4-A

Huawei
SUN2000-125KTL-JPH0
125 kW Grid-tie
VS
SOFAR 125KTLX-G4-A
Sofar Solar
SOFAR 125KTLX-G4-A
125 kW 98.3 % euro Grid-tie
The verdict

SOFAR 125KTLX-G4-A leads on the differences that matter

The largest is max dc voltage: 400 V apart. 8 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
8 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 18 parameters
Parameter SUN2000-125KTL-JPH0 SOFAR 125KTLX-G4-A Difference
Max DC voltage 1500 V 1100 V 400 V apart
Max input current per tracker 26.0 A 40.0 A 14.0 A more headroom
Weight 88.0 kg 75.0 kg 13.0 kg lighter
Nominal AC voltage 550 V 400 V 150 V apart
Max AC current 131.3 A 190.0 A 58.7 A apart
Start voltage 550 V 200 V 350 V earlier start
MPP trackers 9 10 1 tracker more
Max efficiency 98.8 % 98.6 % 0.2 pp more efficient
MPPT voltage range 500-1500 V 180-1000 V 500-1500 V vs 180-1000 V
Dimensions 700x1080x365 mm 695x970x325 mm 700x1080x365 mm vs 695x970x325 mm
02

Full specification

Parameter SUN2000-125KTL-JPH0 SOFAR 125KTLX-G4-A Difference
AC output
Rated AC power 125.00 kW 125.00 kW Same
Max AC power 125.00 kW 125.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 550 V 400 V 150 V apart
Max AC current 131.3 A 190.0 A 58.7 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1500 V 1100 V 400 V apart
MPPT voltage range 500-1500 V 180-1000 V 500-1500 V vs 180-1000 V
Start voltage 550 V 200 V -350 V for SOFAR 125KTLX-G4-A
MPP trackers 9 10 +1 trackers for SOFAR 125KTLX-G4-A
Strings per tracker 2 2 Same
Max input current per tracker 26.0 A 40.0 A +14.0 A for SOFAR 125KTLX-G4-A
Efficiency
European efficiency - 98.3 % Not published by Huawei
Max efficiency 98.8 % 98.6 % +0.2 pp for SUN2000-125KTL-JPH0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 88.0 kg 75.0 kg -13.0 kg for SOFAR 125KTLX-G4-A
Weight per kW 0.7 kg/kW 0.6 kg/kW Effectively the same
Dimensions 700x1080x365 mm 695x970x325 mm 700x1080x365 mm vs 695x970x325 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Huawei
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Huawei
Integrated DC switch - Yes Not published by Huawei
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Huawei SUN2000-125KTL-JPH0 vs Ginlong Solis S5-GC125K-HV
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Huawei SUN2000-125KTL-JPH0 vs Growatt MAX 125KTL3-X LV
10 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Huawei SUN2000-125KTL-JPH0 vs Sungrow SG125CX-P2
10 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
SOFAR 125KTLX-G4-A vs Ginlong Solis S6-GC125K
5 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.