Skip to main content
SUN2000-10KTL-M1 vs SE10K-ILB48 6 of 18 identical Swap Change inverters

Huawei SUN2000-10KTL-M1 vs SolarEdge SE10K-ILB48

Huawei SUN2000-10KTL-M1
Huawei
SUN2000-10KTL-M1
10 kW 98.1 % euro Hybrid
VS
SolarEdge
SE10K-ILB48
10 kW Hybrid
The verdict

SUN2000-10KTL-M1 leads on the differences that matter

The largest is max efficiency: 0.6 pp more efficient. 6 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
6 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 18 parameters
Parameter SUN2000-10KTL-M1 SE10K-ILB48 Difference
Max efficiency 98.6 % 98.0 % 0.6 pp more efficient
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Max PV power 15.00 kW 20.00 kW 5.00 kW apart
DC/AC ratio 1.50 2.00 0.50 more oversizing headroom
Max charge current 16 A 125 A 109 A faster charging
Weight 17.0 kg 37.0 kg 20.0 kg lighter
Weight per kW 1.7 kg/kW 3.7 kg/kW 2.0 kg/kW lighter
MPPT voltage range 140-980 V 750-900 V 140-980 V vs 750-900 V
Battery voltage 600 V ~ 980 V 40 - 62 Vdc 600 V ~ 980 V vs 40 - 62 Vdc
Max AC current 16.9 A 16.0 A 0.9 A apart
Dimensions 525x470x146 mm 907x317x192 mm 525x470x146 mm vs 907x317x192 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-10KTL-M1 SE10K-ILB48 Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 11.00 kW 10.00 kW 1.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 16.9 A 16.0 A 0.9 A apart
PV input
Max PV power 15.00 kW 20.00 kW 5.00 kW apart
DC/AC ratio 1.50 2.00 +0.50 for SE10K-ILB48
Max DC voltage 1100 V - Not published by SolarEdge
MPPT voltage range 140-980 V 750-900 V 140-980 V vs 750-900 V
Start voltage 200 V - Not published by SolarEdge
MPP trackers 2 - Not published by SolarEdge
Strings per tracker 1 - Not published by SolarEdge
Max input current per tracker 11.0 A - Not published by SolarEdge
Efficiency
European efficiency 98.1 % - Not published by SolarEdge
Max efficiency 98.6 % 98.0 % +0.6 pp for SUN2000-10KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600 V ~ 980 V 40 - 62 Vdc 600 V ~ 980 V vs 40 - 62 Vdc
Max charge current 16 A 125 A +109 A for SE10K-ILB48
Backup power 3.3 kW - Not published by SolarEdge
Physical
Weight 17.0 kg 37.0 kg -20.0 kg for SUN2000-10KTL-M1
Weight per kW 1.7 kg/kW 3.7 kg/kW -2.0 kg/kW for SUN2000-10KTL-M1
Dimensions 525x470x146 mm 907x317x192 mm 525x470x146 mm vs 907x317x192 mm
Ingress protection IP65 IP65 Same
Cooling natural forced-air natural vs forced-air
Noise - 50 dB Not published by Huawei
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by SolarEdge
Ethernet Yes - Not published by SolarEdge
Arc fault protection Yes - Not published by SolarEdge
Integrated DC switch Yes - Not published by SolarEdge
Warranty
Warranty - 12 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Huawei SUN2000-10KTL-M1 vs SolarEdge SE10000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-XH
10 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-HU
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.