Huawei SUN2000-10KTL-M1 vs Fronius Symo GEN24 Plus 10.0
VS

Fronius International
Fronius Symo GEN24 Plus 10.0
10 kW
97.9 % euro
Hybrid
The verdict
17 differences, and they point both ways
The largest is max dc voltage: 100 V apart. 9 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
9
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 26 parameters
What actually differs
Parameter
SUN2000-10KTL-M1
Fronius Symo GEN24 Plus 10.0
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
11.0 A
25.0 A
14.0 A more headroom
Max AC power
11.00 kW
10.00 kW
1.00 kW apart
Max PV power
15.00 kW
10.30 kW
4.70 kW apart
DC/AC ratio
1.50
1.03
0.47 more oversizing headroom
Max charge current
16 A
22 A
6 A faster charging
Weight
17.0 kg
23.4 kg
6.4 kg lighter
Weight per kW
1.7 kg/kW
2.3 kg/kW
0.6 kg/kW lighter
Max efficiency
98.6 %
98.2 %
0.4 pp more efficient
European efficiency
98.1 %
97.9 %
0.2 pp more efficient
Start voltage
200 V
80 V
120 V earlier start
Max AC current
16.9 A
15.2 A
1.7 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
140-980 V
80-800 V
140-980 V vs 80-800 V
Battery voltage
600 V ~ 980 V
160 - 700
600 V ~ 980 V vs 160 - 700
Dimensions
525x470x146 mm
595x529x180 mm
525x470x146 mm vs 595x529x180 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-10KTL-M1
Fronius Symo GEN24 Plus 10.0
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
11.00 kW
10.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
16.9 A
15.2 A
1.7 A apart
PV input
Max PV power
15.00 kW
10.30 kW
4.70 kW apart
DC/AC ratio
1.50
1.03
+0.47 for SUN2000-10KTL-M1
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
140-980 V
80-800 V
140-980 V vs 80-800 V
Start voltage
200 V
80 V
-120 V for Fronius Symo GEN24 Plus 10.0
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Fronius International
Max input current per tracker
11.0 A
25.0 A
+14.0 A for Fronius Symo GEN24 Plus 10.0
Efficiency
European efficiency
98.1 %
97.9 %
+0.2 pp for SUN2000-10KTL-M1
Max efficiency
98.6 %
98.2 %
+0.4 pp for SUN2000-10KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600 V ~ 980 V
160 - 700
600 V ~ 980 V vs 160 - 700
Max charge current
16 A
22 A
+6 A for Fronius Symo GEN24 Plus 10.0
Backup power
3.3 kW
-
Not published by Fronius International
Physical
Weight
17.0 kg
23.4 kg
-6.4 kg for SUN2000-10KTL-M1
Weight per kW
1.7 kg/kW
2.3 kg/kW
-0.6 kg/kW for SUN2000-10KTL-M1
Dimensions
525x470x146 mm
595x529x180 mm
525x470x146 mm vs 595x529x180 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
47 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Fronius International
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-10KTL-M1 vs SolarEdge SE10000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-XH
10 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-HU
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.