Huawei SUN2000-10KTL-M1 vs Deye SUN-10K-SG01LP3
VS
The verdict
SUN2000-10KTL-M1 leads on the differences that matter
The largest is european efficiency: 1.1 pp more efficient. 8 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
8
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 22 parameters
What actually differs
Parameter
SUN2000-10KTL-M1
SUN-10K-SG01LP3
Difference
European efficiency
98.1 %
97.0 %
1.1 pp more efficient
Max DC voltage
1100 V
800 V
300 V apart
Max input current per tracker
11.0 A
25.0 A
14.0 A more headroom
Max efficiency
98.6 %
97.6 %
1.0 pp more efficient
Max PV power
15.00 kW
13.00 kW
2.00 kW apart
Weight
17.0 kg
45.0 kg
28.0 kg lighter
Weight per kW
1.7 kg/kW
4.5 kg/kW
2.8 kg/kW lighter
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Start voltage
200 V
160 V
40 V earlier start
MPPT voltage range
140-980 V
140-700 V
140-980 V vs 140-700 V
Battery voltage
600 V ~ 980 V
40-60 V
600 V ~ 980 V vs 40-60 V
Max AC current
16.9 A
16.0 A
0.9 A apart
Dimensions
525x470x146 mm
656x420x281 mm
525x470x146 mm vs 656x420x281 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SUN2000-10KTL-M1
SUN-10K-SG01LP3
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
11.00 kW
11.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
16.9 A
16.0 A
0.9 A apart
PV input
Max PV power
15.00 kW
13.00 kW
2.00 kW apart
DC/AC ratio
1.50
1.30
+0.20 for SUN2000-10KTL-M1
Max DC voltage
1100 V
800 V
300 V apart
MPPT voltage range
140-980 V
140-700 V
140-980 V vs 140-700 V
Start voltage
200 V
160 V
-40 V for SUN-10K-SG01LP3
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Deye
Max input current per tracker
11.0 A
25.0 A
+14.0 A for SUN-10K-SG01LP3
Efficiency
European efficiency
98.1 %
97.0 %
+1.1 pp for SUN2000-10KTL-M1
Max efficiency
98.6 %
97.6 %
+1.0 pp for SUN2000-10KTL-M1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600 V ~ 980 V
40-60 V
600 V ~ 980 V vs 40-60 V
Max charge current
16 A
-
Not published by Deye
Backup power
3.3 kW
-
Not published by Deye
Physical
Weight
17.0 kg
45.0 kg
-28.0 kg for SUN2000-10KTL-M1
Weight per kW
1.7 kg/kW
4.5 kg/kW
-2.8 kg/kW for SUN2000-10KTL-M1
Dimensions
525x470x146 mm
656x420x281 mm
525x470x146 mm vs 656x420x281 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
30 dB
Not published by Huawei
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Deye
Ethernet
Yes
-
Not published by Deye
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
-
Not published by Deye
Warranty
Warranty
-
5 yrs
Not published by Huawei
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Huawei SUN2000-10KTL-M1 vs SolarEdge SE10000H
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-XH
10 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Huawei SUN2000-10KTL-M1 vs Growatt MOD 10KTL3-HU
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.