105KTL-H1 vs 100KTL-M1 (@480 V) 6 of 20 identical Swap Change inverters

Huawei SUN2000-105KTL-H1 vs Huawei SUN2000-100KTL-M1 (@480 V)

Huawei SUN2000-105KTL-H1
Huawei
SUN2000-105KTL-H1
105 kW 98.8 % euro Grid-tie
VS
Huawei SUN2000-100KTL-M1 (@480 V)
Huawei
SUN2000-100KTL-M1 (@480 V)
100 kW 98.6 % euro Grid-tie
The verdict

100KTL-M1 (@480 V) leads on the differences that matter

The largest is rated ac power: 5.00 kW apart. 6 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
6 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 20 parameters
Parameter 105KTL-H1 100KTL-M1 (@480 V) Difference
Rated AC power 105.00 kW 100.00 kW 5.00 kW apart
MPP trackers 6 10 4 trackers more
Max DC voltage 1500 V 1100 V 400 V apart
Max AC power 116.00 kW 110.00 kW 6.00 kW apart
Weight 79.0 kg 90.0 kg 11.0 kg lighter
Max input current per tracker 25.0 A 26.0 A 1.0 A more headroom
European efficiency 98.8 % 98.6 % 0.2 pp more efficient
Max AC current 84.6 A 133.7 A 49.1 A apart
Start voltage 650 V 200 V 450 V earlier start
Max efficiency 99.0 % 98.8 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 600-1500 V 200-1000 V 600-1500 V vs 200-1000 V
Dimensions 605x1075x310 mm 700x1035x365 mm 605x1075x310 mm vs 700x1035x365 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter 105KTL-H1 100KTL-M1 (@480 V) Difference
AC output
Rated AC power 105.00 kW 100.00 kW 5.00 kW apart
Max AC power 116.00 kW 110.00 kW 6.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 800 V - Not published by Huawei
Max AC current 84.6 A 133.7 A 49.1 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1500 V 1100 V 400 V apart
MPPT voltage range 600-1500 V 200-1000 V 600-1500 V vs 200-1000 V
Start voltage 650 V 200 V -450 V for 100KTL-M1 (@480 V)
MPP trackers 6 10 +4 trackers for 100KTL-M1 (@480 V)
Strings per tracker 2 2 Same
Max input current per tracker 25.0 A 26.0 A +1.0 A for 100KTL-M1 (@480 V)
Efficiency
European efficiency 98.8 % 98.6 % +0.2 pp for 105KTL-H1
Max efficiency 99.0 % 98.8 % +0.2 pp for 105KTL-H1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 79.0 kg 90.0 kg -11.0 kg for 105KTL-H1
Weight per kW 0.8 kg/kW 0.9 kg/kW Effectively the same
Dimensions 605x1075x310 mm 700x1035x365 mm 605x1075x310 mm vs 700x1035x365 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Huawei SUN2000-105KTL-H1 vs Huawei SUN2000-100KTL-M2
15 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
Huawei SUN2000-105KTL-H1 vs Ginlong Solis S5-GC110K
14 differences, the largest is rated ac power
Same type, similar size
Sungrow
Huawei SUN2000-105KTL-H1 vs Sungrow SG110CX
15 differences, the largest is rated ac power
Same type, similar size
SMA Solar
Huawei SUN2000-100KTL-M1 (@480 V) vs SMA Solar Sunny Highpower PEAK3 SHP 100-21
8 differences, the largest is mpp trackers
Same type, similar size
SMA Solar
Huawei SUN2000-100KTL-M1 (@480 V) vs SMA Solar Sunny Highpower Storage SHPS 100-21
6 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.