Huawei SUN2000-100KTL-M2 vs Huawei SUN2000-105KTL-H1
VS
The verdict
100KTL-M2 leads on the differences that matter
The largest is rated ac power: 5.00 kW apart. 6 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
6
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 21 parameters
What actually differs
Parameter
100KTL-M2
105KTL-H1
Difference
Rated AC power
100.00 kW
105.00 kW
5.00 kW apart
MPP trackers
10
6
4 trackers more
Max DC voltage
1100 V
1500 V
400 V apart
Max input current per tracker
30.0 A
25.0 A
5.0 A more headroom
Max AC power
110.00 kW
116.00 kW
6.00 kW apart
Weight
93.0 kg
79.0 kg
14.0 kg lighter
European efficiency
98.6 %
98.8 %
0.2 pp more efficient
Nominal AC voltage
400 V
800 V
400 V apart
Max AC current
160.4 A
84.6 A
75.8 A apart
Start voltage
200 V
650 V
450 V earlier start
Max efficiency
98.8 %
99.0 %
0.2 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
200-1000 V
600-1500 V
200-1000 V vs 600-1500 V
Dimensions
700x1035x365 mm
605x1075x310 mm
700x1035x365 mm vs 605x1075x310 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
100KTL-M2
105KTL-H1
Difference
AC output
Rated AC power
100.00 kW
105.00 kW
5.00 kW apart
Max AC power
110.00 kW
116.00 kW
6.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
800 V
400 V apart
Max AC current
160.4 A
84.6 A
75.8 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1500 V
400 V apart
MPPT voltage range
200-1000 V
600-1500 V
200-1000 V vs 600-1500 V
Start voltage
200 V
650 V
-450 V for 100KTL-M2
MPP trackers
10
6
+4 trackers for 100KTL-M2
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
25.0 A
+5.0 A for 100KTL-M2
Efficiency
European efficiency
98.6 %
98.8 %
+0.2 pp for 105KTL-H1
Max efficiency
98.8 %
99.0 %
+0.2 pp for 105KTL-H1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
93.0 kg
79.0 kg
-14.0 kg for 105KTL-H1
Weight per kW
0.9 kg/kW
0.8 kg/kW
Effectively the same
Dimensions
700x1035x365 mm
605x1075x310 mm
700x1035x365 mm vs 605x1075x310 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
natural
forced-air vs natural
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Huawei
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Huawei SUN2000-100KTL-M2 vs Huawei SUN2000-100KTL-M1 (@480 V)
3 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Huawei SUN2000-100KTL-M2 vs Sungrow SG110CX
6 differences, the largest is max input current per tracker
Same type, similar size
SMA Solar
Huawei SUN2000-100KTL-M2 vs SMA Solar Sunny Highpower PEAK3 SHP 100-21
8 differences, the largest is mpp trackers
Same type, similar size
Ginlong Solis
Huawei SUN2000-105KTL-H1 vs Ginlong Solis S5-GC110K
14 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.