Growatt WIT 36K-XHU vs Ginlong Solis S6-EH3P35K-H-LV(21A)
VS
The verdict
16 differences, and they point both ways
The largest is rated ac power: 1.00 kW apart. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
7
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 23 parameters
What actually differs
Parameter
WIT 36K-XHU
S6-EH3P35K-H-LV(21A)
Difference
Rated AC power
36.00 kW
35.00 kW
1.00 kW apart
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
40.0 A
42.0 A
2.0 A more headroom
Max efficiency
98.1 %
96.3 %
1.8 pp more efficient
Max AC power
36.00 kW
35.00 kW
1.00 kW apart
Max PV power
72.00 kW
70.00 kW
2.00 kW apart
Max charge current
165 A
160 A
5 A faster charging
Weight
90.0 kg
76.0 kg
14.0 kg lighter
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
60.0 A
152.0 A
92.0 A apart
MPP trackers
4
3
1 tracker more
Weight per kW
2.5 kg/kW
2.2 kg/kW
0.3 kg/kW lighter
MPPT voltage range
180-1000 V
150-850 V
180-1000 V vs 150-850 V
Battery voltage
200-900V
150 - 800 V
200-900V vs 150 - 800 V
Start voltage
195 V
180 V
15 V earlier start
Dimensions
585x920x320 mm
880x530x290 mm
585x920x320 mm vs 880x530x290 mm
02
Full specification
Parameter
WIT 36K-XHU
S6-EH3P35K-H-LV(21A)
Difference
AC output
Rated AC power
36.00 kW
35.00 kW
1.00 kW apart
Max AC power
36.00 kW
35.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
60.0 A
152.0 A
92.0 A apart
PV input
Max PV power
72.00 kW
70.00 kW
2.00 kW apart
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
180-1000 V
150-850 V
180-1000 V vs 150-850 V
Start voltage
195 V
180 V
-15 V for S6-EH3P35K-H-LV(21A)
MPP trackers
4
3
+1 trackers for WIT 36K-XHU
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
42.0 A
+2.0 A for S6-EH3P35K-H-LV(21A)
Efficiency
European efficiency
-
95.5 %
Not published by Growatt
Max efficiency
98.1 %
96.3 %
+1.8 pp for WIT 36K-XHU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
200-900V
150 - 800 V
200-900V vs 150 - 800 V
Max charge current
165 A
160 A
+5 A for WIT 36K-XHU
Backup power
-
35.0 kW
Not published by Growatt
Physical
Weight
90.0 kg
76.0 kg
-14.0 kg for S6-EH3P35K-H-LV(21A)
Weight per kW
2.5 kg/kW
2.2 kg/kW
-0.3 kg/kW for S6-EH3P35K-H-LV(21A)
Dimensions
585x920x320 mm
880x530x290 mm
585x920x320 mm vs 880x530x290 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt WIT 36K-XHU vs Growatt MID 36K-HU
9 differences, the largest is max dc voltage
Same type, similar size
PowMr
Growatt WIT 36K-XHU vs PowMr SOLXPOW X4-36K
6 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt WIT 36K-XHU vs Deye SUN-35K-SG01HP3-EU-BM3
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2
8 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.