Skip to main content
WIT 36K-XHU vs S6-EH3P35K-H-LV(21A) 7 of 23 identical Swap Change inverters

Growatt WIT 36K-XHU vs Ginlong Solis S6-EH3P35K-H-LV(21A)

Growatt WIT 36K-XHU
Growatt
WIT 36K-XHU
36 kW Hybrid
VS
Ginlong Solis S6-EH3P35K-H-LV(21A)
Ginlong Solis
S6-EH3P35K-H-LV(21A)
35 kW 95.5 % euro Hybrid
The verdict

16 differences, and they point both ways

The largest is rated ac power: 1.00 kW apart. 7 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
7 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 23 parameters
Parameter WIT 36K-XHU S6-EH3P35K-H-LV(21A) Difference
Rated AC power 36.00 kW 35.00 kW 1.00 kW apart
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 40.0 A 42.0 A 2.0 A more headroom
Max efficiency 98.1 % 96.3 % 1.8 pp more efficient
Max AC power 36.00 kW 35.00 kW 1.00 kW apart
Max PV power 72.00 kW 70.00 kW 2.00 kW apart
Max charge current 165 A 160 A 5 A faster charging
Weight 90.0 kg 76.0 kg 14.0 kg lighter
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 60.0 A 152.0 A 92.0 A apart
MPP trackers 4 3 1 tracker more
Weight per kW 2.5 kg/kW 2.2 kg/kW 0.3 kg/kW lighter
MPPT voltage range 180-1000 V 150-850 V 180-1000 V vs 150-850 V
Battery voltage 200-900V 150 - 800 V 200-900V vs 150 - 800 V
Start voltage 195 V 180 V 15 V earlier start
Dimensions 585x920x320 mm 880x530x290 mm 585x920x320 mm vs 880x530x290 mm
02

Full specification

Parameter WIT 36K-XHU S6-EH3P35K-H-LV(21A) Difference
AC output
Rated AC power 36.00 kW 35.00 kW 1.00 kW apart
Max AC power 36.00 kW 35.00 kW 1.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 60.0 A 152.0 A 92.0 A apart
PV input
Max PV power 72.00 kW 70.00 kW 2.00 kW apart
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 180-1000 V 150-850 V 180-1000 V vs 150-850 V
Start voltage 195 V 180 V -15 V for S6-EH3P35K-H-LV(21A)
MPP trackers 4 3 +1 trackers for WIT 36K-XHU
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 42.0 A +2.0 A for S6-EH3P35K-H-LV(21A)
Efficiency
European efficiency - 95.5 % Not published by Growatt
Max efficiency 98.1 % 96.3 % +1.8 pp for WIT 36K-XHU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 200-900V 150 - 800 V 200-900V vs 150 - 800 V
Max charge current 165 A 160 A +5 A for WIT 36K-XHU
Backup power - 35.0 kW Not published by Growatt
Physical
Weight 90.0 kg 76.0 kg -14.0 kg for S6-EH3P35K-H-LV(21A)
Weight per kW 2.5 kg/kW 2.2 kg/kW -0.3 kg/kW for S6-EH3P35K-H-LV(21A)
Dimensions 585x920x320 mm 880x530x290 mm 585x920x320 mm vs 880x530x290 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet Yes - Not published by Ginlong Solis
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt WIT 36K-XHU vs Growatt MID 36K-HU
9 differences, the largest is max dc voltage
Same type, similar size
PowMr
Growatt WIT 36K-XHU vs PowMr SOLXPOW X4-36K
6 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt WIT 36K-XHU vs Deye SUN-35K-SG01HP3-EU-BM3
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EH3P35K-H-LV(21A) vs Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2
8 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.