Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Ginlong Solis S6-EH3P35K-H-LV(21A)
VS
The verdict
8 differences, and they point both ways
The largest is max efficiency: 1.7 pp more efficient. 4 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
4
of 12 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 12 parameters
What actually differs
Parameter
WIT 35K-A-US L2 / WIT 35K-AU-US L2
S6-EH3P35K-H-LV(21A)
Difference
Max efficiency
98.0 %
96.3 %
1.7 pp more efficient
Max AC power
38.50 kW
35.00 kW
3.50 kW apart
Weight
120.0 kg
76.0 kg
44.0 kg lighter
Weight per kW
3.4 kg/kW
2.2 kg/kW
1.3 kg/kW lighter
Max AC current
106.9 A
152.0 A
45.1 A apart
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
Battery voltage
380~450V
150 - 800 V
380~450V vs 150 - 800 V
Dimensions
820x1350x501 mm
880x530x290 mm
820x1350x501 mm vs 880x530x290 mm
02
Full specification
Parameter
WIT 35K-A-US L2 / WIT 35K-AU-US L2
S6-EH3P35K-H-LV(21A)
Difference
AC output
Rated AC power
35.00 kW
35.00 kW
Same
Max AC power
38.50 kW
35.00 kW
3.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
-
230 V
Not published by Growatt
Max AC current
106.9 A
152.0 A
45.1 A apart
PV input
Max PV power
-
70.00 kW
Not published by Growatt
DC/AC ratio
-
2.00
Not published by Growatt
Max DC voltage
-
1000 V
Not published by Growatt
MPPT voltage range
-
150-850 V
Not published by Growatt
Start voltage
-
180 V
Not published by Growatt
MPP trackers
-
3
Not published by Growatt
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
-
42.0 A
Not published by Growatt
Efficiency
European efficiency
-
95.5 %
Not published by Growatt
Max efficiency
98.0 %
96.3 %
+1.7 pp for WIT 35K-A-US L2 / WIT 35K-AU-US L2
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
380~450V
150 - 800 V
380~450V vs 150 - 800 V
Max charge current
-
160 A
Not published by Growatt
Backup power
-
35.0 kW
Not published by Growatt
Physical
Weight
120.0 kg
76.0 kg
-44.0 kg for S6-EH3P35K-H-LV(21A)
Weight per kW
3.4 kg/kW
2.2 kg/kW
-1.3 kg/kW for S6-EH3P35K-H-LV(21A)
Dimensions
820x1350x501 mm
880x530x290 mm
820x1350x501 mm vs 880x530x290 mm
Ingress protection
IP66/NEMA 4X
IP66
IP66/NEMA 4X vs IP66
Cooling
-
forced-air
Not published by Growatt
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Deye
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Deye SUN-35K-SG01HP3-EU-BM3
7 differences, the largest is weight
Same type, similar size
Growatt
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
6 differences, the largest is max ac power
Same type, similar size
Growatt
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Growatt MID 36K-HU
9 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.