Skip to main content
WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs S6-EH3P35K-H-LV(21A) 4 of 12 identical Swap Change inverters

Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Ginlong Solis S6-EH3P35K-H-LV(21A)

Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2
Growatt
WIT 35K-A-US L2 / WIT 35K-AU-US L2
35 kW Hybrid
VS
Ginlong Solis S6-EH3P35K-H-LV(21A)
Ginlong Solis
S6-EH3P35K-H-LV(21A)
35 kW 95.5 % euro Hybrid
The verdict

8 differences, and they point both ways

The largest is max efficiency: 1.7 pp more efficient. 4 of 12 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
4 of 12 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 12 parameters
Parameter WIT 35K-A-US L2 / WIT 35K-AU-US L2 S6-EH3P35K-H-LV(21A) Difference
Max efficiency 98.0 % 96.3 % 1.7 pp more efficient
Max AC power 38.50 kW 35.00 kW 3.50 kW apart
Weight 120.0 kg 76.0 kg 44.0 kg lighter
Weight per kW 3.4 kg/kW 2.2 kg/kW 1.3 kg/kW lighter
Max AC current 106.9 A 152.0 A 45.1 A apart
Ingress protection IP66/NEMA 4X IP66 IP66/NEMA 4X vs IP66
Battery voltage 380~450V 150 - 800 V 380~450V vs 150 - 800 V
Dimensions 820x1350x501 mm 880x530x290 mm 820x1350x501 mm vs 880x530x290 mm
02

Full specification

Parameter WIT 35K-A-US L2 / WIT 35K-AU-US L2 S6-EH3P35K-H-LV(21A) Difference
AC output
Rated AC power 35.00 kW 35.00 kW Same
Max AC power 38.50 kW 35.00 kW 3.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage - 230 V Not published by Growatt
Max AC current 106.9 A 152.0 A 45.1 A apart
PV input
Max PV power - 70.00 kW Not published by Growatt
DC/AC ratio - 2.00 Not published by Growatt
Max DC voltage - 1000 V Not published by Growatt
MPPT voltage range - 150-850 V Not published by Growatt
Start voltage - 180 V Not published by Growatt
MPP trackers - 3 Not published by Growatt
Strings per tracker - 2 Not published by Growatt
Max input current per tracker - 42.0 A Not published by Growatt
Efficiency
European efficiency - 95.5 % Not published by Growatt
Max efficiency 98.0 % 96.3 % +1.7 pp for WIT 35K-A-US L2 / WIT 35K-AU-US L2
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 380~450V 150 - 800 V 380~450V vs 150 - 800 V
Max charge current - 160 A Not published by Growatt
Backup power - 35.0 kW Not published by Growatt
Physical
Weight 120.0 kg 76.0 kg -44.0 kg for S6-EH3P35K-H-LV(21A)
Weight per kW 3.4 kg/kW 2.2 kg/kW -1.3 kg/kW for S6-EH3P35K-H-LV(21A)
Dimensions 820x1350x501 mm 880x530x290 mm 820x1350x501 mm vs 880x530x290 mm
Ingress protection IP66/NEMA 4X IP66 IP66/NEMA 4X vs IP66
Cooling - forced-air Not published by Growatt
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Deye
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Deye SUN-35K-SG01HP3-EU-BM3
7 differences, the largest is weight
Same type, similar size
Growatt
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Growatt WT 35K-H-US L2 / WT 35K-HU-US L2
6 differences, the largest is max ac power
Same type, similar size
Growatt
Growatt WIT 35K-A-US L2 / WIT 35K-AU-US L2 vs Growatt MID 36K-HU
9 differences, the largest is rated ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.