Growatt WIT 29.9K-XHU vs Growatt WT 28K-H-US L2 / WT 28K-HU-US L2
VS
The verdict
WIT 29.9K-XHU leads on the differences that matter
The largest is rated ac power: 1.90 kW apart. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
7
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 21 parameters
What actually differs
Parameter
WIT 29.9K-XHU
WT 28K-H-US L2 / WT 28K-HU-US L2
Difference
Rated AC power
29.90 kW
28.00 kW
1.90 kW apart
Max DC voltage
1100 V
800 V
300 V apart
Max input current per tracker
40.0 A
32.0 A
8.0 A more headroom
Max AC power
29.90 kW
28.00 kW
1.90 kW apart
Max PV power
59.80 kW
54.00 kW
5.80 kW apart
MPP trackers
4
2
2 trackers more
Weight
90.0 kg
133.0 kg
43.0 kg lighter
Weight per kW
3.0 kg/kW
4.8 kg/kW
1.7 kg/kW lighter
Nominal AC voltage
400 V
208 V
192 V apart
Max AC current
45.3 A
85.6 A
40.3 A apart
DC/AC ratio
2.00
1.93
0.07 more oversizing headroom
MPPT voltage range
180-1000 V
180-600 V
180-1000 V vs 180-600 V
Battery voltage
200-900V
380-650V
200-900V vs 380-650V
Dimensions
585x920x320 mm
1350x820x501 mm
585x920x320 mm vs 1350x820x501 mm
02
Full specification
Parameter
WIT 29.9K-XHU
WT 28K-H-US L2 / WT 28K-HU-US L2
Difference
AC output
Rated AC power
29.90 kW
28.00 kW
1.90 kW apart
Max AC power
29.90 kW
28.00 kW
1.90 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
208 V
192 V apart
Max AC current
45.3 A
85.6 A
40.3 A apart
PV input
Max PV power
59.80 kW
54.00 kW
5.80 kW apart
DC/AC ratio
2.00
1.93
+0.07 for WIT 29.9K-XHU
Max DC voltage
1100 V
800 V
300 V apart
MPPT voltage range
180-1000 V
180-600 V
180-1000 V vs 180-600 V
Start voltage
195 V
195 V
Same
MPP trackers
4
2
+2 trackers for WIT 29.9K-XHU
Strings per tracker
2
-
Not published by Growatt
Max input current per tracker
40.0 A
32.0 A
+8.0 A for WIT 29.9K-XHU
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
98.1 %
98.0 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
200-900V
380-650V
200-900V vs 380-650V
Max charge current
165 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
90.0 kg
133.0 kg
-43.0 kg for WIT 29.9K-XHU
Weight per kW
3.0 kg/kW
4.8 kg/kW
-1.7 kg/kW for WIT 29.9K-XHU
Dimensions
585x920x320 mm
1350x820x501 mm
585x920x320 mm vs 1350x820x501 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Growatt
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
5 yrs
-
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt WIT 29.9K-XHU vs Growatt MID 29.9K-HU
9 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt WIT 29.9K-XHU vs Deye SUN-29.9K-SG01HP3-EU-BM3
14 differences, the largest is max dc voltage
Same type, similar size
Fronius International
Growatt WIT 29.9K-XHU vs Fronius Verto 30.0 Plus
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt WT 28K-H-US L2 / WT 28K-HU-US L2 vs Growatt WIT 28K-A-US L2 / WIT 28K-AU-US L2
6 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.