Skip to main content
SPM 3600TL-HU vs 3.6KW 7 of 19 identical Swap Change inverters

Growatt SPM 3600TL-HU vs Easun Power 3.6KW

Growatt SPM 3600TL-HU
Growatt
SPM 3600TL-HU
3.6 kW 97.6 % euro Hybrid
VS
Easun Power 3.6KW
Easun Power
3.6KW
3.6 kW Hybrid
The verdict

12 differences, and they point both ways

The largest is max dc voltage: 100 V apart. 7 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 19 parameters
Parameter SPM 3600TL-HU 3.6KW Difference
Max DC voltage 600 V 500 V 100 V apart
Max efficiency 98.1 % 93.0 % 5.1 pp more efficient
Max PV power 5.40 kW 6.20 kW 0.80 kW apart
DC/AC ratio 1.50 1.72 0.22 more oversizing headroom
Max charge current 140 A 120 A 20 A faster charging
Weight 26.0 kg 8.0 kg 18.0 kg lighter
Weight per kW 7.2 kg/kW 2.2 kg/kW 5.0 kg/kW lighter
Max operating temperature 60 °C 50 °C 10 °C more heat tolerant
MPPT voltage range 150-550 V 60-500 V 150-550 V vs 60-500 V
Battery voltage 40-60V 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 40-60V vs 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW)
Dimensions 330x580x230 mm 442x358x116 mm 330x580x230 mm vs 442x358x116 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SPM 3600TL-HU 3.6KW Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.60 kW 3.60 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 15.7 A 15.7 A Same
PV input
Max PV power 5.40 kW 6.20 kW 0.80 kW apart
DC/AC ratio 1.50 1.72 +0.22 for 3.6KW
Max DC voltage 600 V 500 V 100 V apart
MPPT voltage range 150-550 V 60-500 V 150-550 V vs 60-500 V
Start voltage 130 V - Not published by Easun Power
MPP trackers 2 - Not published by Easun Power
Strings per tracker 1 - Not published by Easun Power
Max input current per tracker 22.0 A - Not published by Easun Power
Efficiency
European efficiency 97.6 % - Not published by Easun Power
Max efficiency 98.1 % 93.0 % +5.1 pp for SPM 3600TL-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40-60V 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 40-60V vs 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW)
Max charge current 140 A 120 A +20 A for SPM 3600TL-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 26.0 kg 8.0 kg -18.0 kg for 3.6KW
Weight per kW 7.2 kg/kW 2.2 kg/kW -5.0 kg/kW for 3.6KW
Dimensions 330x580x230 mm 442x358x116 mm 330x580x230 mm vs 442x358x116 mm
Ingress protection IP65 - Not published by Easun Power
Cooling natural forced-air natural vs forced-air
Noise 30 dB - Not published by Easun Power
Max operating temperature 60 °C 50 °C +10 °C for SPM 3600TL-HU
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Easun Power
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty 5 yrs - Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPM 3600TL-HU vs Growatt MIN 3600TL-XH
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPM 3600TL-HU vs Growatt MIN 3600TL-XA
7 differences, the largest is warranty
Same type, similar size
Growatt
Growatt SPM 3600TL-HU vs Growatt MIN 3600TL-XH2
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.