Skip to main content
SPH3000TL BL-UP vs MOD 3000TL3-HU 7 of 26 identical Swap Change inverters

Growatt SPH3000TL BL-UP vs Growatt MOD 3000TL3-HU

Growatt SPH3000TL BL-UP
Growatt
SPH3000TL BL-UP
3 kW 97.0 % euro Hybrid
VS
Growatt MOD 3000TL3-HU
Growatt
MOD 3000TL3-HU
3 kW 97.8 % euro Hybrid
The verdict

MOD 3000TL3-HU leads on the differences that matter

The largest is european efficiency: 0.8 pp more efficient. 7 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
7 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 26 parameters
Parameter SPH3000TL BL-UP MOD 3000TL3-HU Difference
European efficiency 97.0 % 97.8 % 0.8 pp more efficient
Warranty 5 yrs 10 yrs 5 yrs longer
Max DC voltage 550 V 1000 V 450 V apart
Max input current per tracker 13.5 A 20.0 A 6.5 A more headroom
Max efficiency 97.2 % 98.3 % 1.1 pp more efficient
Max AC power 3.00 kW 3.30 kW 0.30 kW apart
Max PV power 6.50 kW 6.00 kW 0.50 kW apart
Max charge current 86 A 25 A 61 A faster charging
Weight 27.0 kg 19.0 kg 8.0 kg lighter
Weight per kW 9.0 kg/kW 6.3 kg/kW 2.7 kg/kW lighter
DC/AC ratio 2.17 2.00 0.17 more oversizing headroom
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 13.5 A 5.0 A 8.5 A apart
Start voltage 120 V 180 V 60 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 120-550 V 140-1000 V 120-550 V vs 140-1000 V
Battery voltage 42-59V 600-980 V 42-59V vs 600-980 V
Dimensions 456x565x188 mm 468x408x202 mm 456x565x188 mm vs 468x408x202 mm
02

Full specification

Parameter SPH3000TL BL-UP MOD 3000TL3-HU Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.30 kW 0.30 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 13.5 A 5.0 A 8.5 A apart
PV input
Max PV power 6.50 kW 6.00 kW 0.50 kW apart
DC/AC ratio 2.17 2.00 +0.17 for SPH3000TL BL-UP
Max DC voltage 550 V 1000 V 450 V apart
MPPT voltage range 120-550 V 140-1000 V 120-550 V vs 140-1000 V
Start voltage 120 V 180 V -60 V for SPH3000TL BL-UP
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 13.5 A 20.0 A +6.5 A for MOD 3000TL3-HU
Efficiency
European efficiency 97.0 % 97.8 % +0.8 pp for MOD 3000TL3-HU
Max efficiency 97.2 % 98.3 % +1.1 pp for MOD 3000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-59V 600-980 V 42-59V vs 600-980 V
Max charge current 86 A 25 A +61 A for SPH3000TL BL-UP
Backup power 4.0 kW - Not published by Growatt
Physical
Weight 27.0 kg 19.0 kg -8.0 kg for MOD 3000TL3-HU
Weight per kW 9.0 kg/kW 6.3 kg/kW -2.7 kg/kW for MOD 3000TL3-HU
Dimensions 456x565x188 mm 468x408x202 mm 456x565x188 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 29 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Growatt
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 10 yrs +5 yrs for MOD 3000TL3-HU
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt SPH3000TL BL-UP vs SolarEdge SE3000H
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPH3000TL BL-UP vs Growatt SPM 3000TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt SPH3000TL BL-UP vs Huawei SUN2000L-3KTL
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt MOD 3000TL3-XH
9 differences, the largest is warranty
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.