Growatt SPH 7000TL3 BH-UP vs SolarEdge SE7K-ILB48
VS
The verdict
SE7K-ILB48 leads on the differences that matter
The largest is warranty: 7 yrs longer. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
SPH 7000TL3 BH-UP
SE7K-ILB48
Difference
Warranty
5 yrs
12 yrs
7 yrs longer
Max PV power
10.50 kW
14.00 kW
3.50 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Max charge current
25 A
125 A
100 A faster charging
Weight
30.0 kg
37.0 kg
7.0 kg lighter
Weight per kW
4.3 kg/kW
5.3 kg/kW
1.0 kg/kW lighter
European efficiency
97.4 %
97.6 %
0.2 pp more efficient
Max efficiency
98.2 %
98.0 %
0.2 pp more efficient
MPPT voltage range
120-1000 V
750-900 V
120-1000 V vs 750-900 V
Battery voltage
100-550 V
40 - 62 Vdc
100-550 V vs 40 - 62 Vdc
Dimensions
453x505x198 mm
907x317x192 mm
453x505x198 mm vs 907x317x192 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
SPH 7000TL3 BH-UP
SE7K-ILB48
Difference
AC output
Rated AC power
7.00 kW
7.00 kW
Same
Max AC power
7.00 kW
7.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
10.6 A
11.0 A
Effectively the same
PV input
Max PV power
10.50 kW
14.00 kW
3.50 kW apart
DC/AC ratio
1.50
2.00
+0.50 for SE7K-ILB48
Max DC voltage
1000 V
-
Not published by SolarEdge
MPPT voltage range
120-1000 V
750-900 V
120-1000 V vs 750-900 V
Start voltage
120 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
13.5 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.4 %
97.6 %
+0.2 pp for SE7K-ILB48
Max efficiency
98.2 %
98.0 %
+0.2 pp for SPH 7000TL3 BH-UP
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
100-550 V
40 - 62 Vdc
100-550 V vs 40 - 62 Vdc
Max charge current
25 A
125 A
+100 A for SE7K-ILB48
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.0 kg
37.0 kg
-7.0 kg for SPH 7000TL3 BH-UP
Weight per kW
4.3 kg/kW
5.3 kg/kW
-1.0 kg/kW for SPH 7000TL3 BH-UP
Dimensions
453x505x198 mm
907x317x192 mm
453x505x198 mm vs 907x317x192 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
forced-air
natural vs forced-air
Noise
-
50 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
5 yrs
12 yrs
+7 yrs for SE7K-ILB48
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt SPH 7000TL3 BH-UP vs Growatt MOD 7000TL3-XH
15 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPH 7000TL3 BH-UP vs Growatt MOD 7000TL3-HU
15 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPH 7000TL3 BH-UP vs Growatt SPA 7000TL3 BH-UP
The same specification on paper
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.