Growatt SPH 4000TL3 BH-UP vs Growatt SPM 4000TL-HU
VS
The verdict
SPM 4000TL-HU leads on the differences that matter
The largest is european efficiency: 0.6 pp more efficient. 11 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
11
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 25 parameters
What actually differs
Parameter
SPH 4000TL3 BH-UP
SPM 4000TL-HU
Difference
European efficiency
97.0 %
97.6 %
0.6 pp more efficient
Max DC voltage
1000 V
600 V
400 V apart
Max input current per tracker
13.5 A
22.0 A
8.5 A more headroom
Max charge current
25 A
140 A
115 A faster charging
Weight
30.0 kg
26.0 kg
4.0 kg lighter
Weight per kW
7.5 kg/kW
6.5 kg/kW
1.0 kg/kW lighter
Max efficiency
97.6 %
98.1 %
0.5 pp more efficient
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.1 A
17.4 A
11.3 A apart
MPPT voltage range
120-1000 V
150-550 V
120-1000 V vs 150-550 V
Battery voltage
100-550 V
40-60V
100-550 V vs 40-60V
Start voltage
120 V
130 V
10 V earlier start
Dimensions
453x505x198 mm
330x580x230 mm
453x505x198 mm vs 330x580x230 mm
02
Full specification
Parameter
SPH 4000TL3 BH-UP
SPM 4000TL-HU
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.00 kW
4.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.1 A
17.4 A
11.3 A apart
PV input
Max PV power
6.00 kW
6.00 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
120-1000 V
150-550 V
120-1000 V vs 150-550 V
Start voltage
120 V
130 V
-10 V for SPH 4000TL3 BH-UP
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
13.5 A
22.0 A
+8.5 A for SPM 4000TL-HU
Efficiency
European efficiency
97.0 %
97.6 %
+0.6 pp for SPM 4000TL-HU
Max efficiency
97.6 %
98.1 %
+0.5 pp for SPM 4000TL-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
100-550 V
40-60V
100-550 V vs 40-60V
Max charge current
25 A
140 A
+115 A for SPM 4000TL-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.0 kg
26.0 kg
-4.0 kg for SPM 4000TL-HU
Weight per kW
7.5 kg/kW
6.5 kg/kW
-1.0 kg/kW for SPM 4000TL-HU
Dimensions
453x505x198 mm
330x580x230 mm
453x505x198 mm vs 330x580x230 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Growatt
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt SPH 4000TL3 BH-UP vs SolarEdge SE4000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt SPH 4000TL3 BH-UP vs Huawei SUN2000L-4KTL
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPH 4000TL3 BH-UP vs Growatt MOD 4000TL3-HU
15 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPM 4000TL-HU vs Growatt MOD 4000TL3-XH
16 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.