Growatt SPH 10000TL3 BH-UP vs Growatt MOD 10KTL3-XH
VS
The verdict
MOD 10KTL3-XH leads on the differences that matter
The largest is european efficiency: 0.6 pp more efficient. 10 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
10
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 25 parameters
What actually differs
Parameter
SPH 10000TL3 BH-UP
MOD 10KTL3-XH
Difference
European efficiency
97.5 %
98.1 %
0.6 pp more efficient
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
13.5 A
16.0 A
2.5 A more headroom
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Max PV power
15.00 kW
20.00 kW
5.00 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Weight
30.0 kg
14.0 kg
16.0 kg lighter
Weight per kW
3.0 kg/kW
1.4 kg/kW
1.6 kg/kW lighter
Max efficiency
98.2 %
98.6 %
0.4 pp more efficient
Start voltage
120 V
160 V
40 V earlier start
Max AC current
15.2 A
16.7 A
1.5 A apart
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
120-1000 V
140-1000 V
120-1000 V vs 140-1000 V
Battery voltage
100-550 V
600-950 V
100-550 V vs 600-950 V
Dimensions
453x505x198 mm
387x425x178 mm
453x505x198 mm vs 387x425x178 mm
02
Full specification
Parameter
SPH 10000TL3 BH-UP
MOD 10KTL3-XH
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
11.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
15.2 A
16.7 A
1.5 A apart
PV input
Max PV power
15.00 kW
20.00 kW
5.00 kW apart
DC/AC ratio
1.50
2.00
+0.50 for MOD 10KTL3-XH
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
120-1000 V
140-1000 V
120-1000 V vs 140-1000 V
Start voltage
120 V
160 V
-40 V for SPH 10000TL3 BH-UP
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
13.5 A
16.0 A
+2.5 A for MOD 10KTL3-XH
Efficiency
European efficiency
97.5 %
98.1 %
+0.6 pp for MOD 10KTL3-XH
Max efficiency
98.2 %
98.6 %
+0.4 pp for MOD 10KTL3-XH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
100-550 V
600-950 V
100-550 V vs 600-950 V
Max charge current
25 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
30.0 kg
14.0 kg
-16.0 kg for MOD 10KTL3-XH
Weight per kW
3.0 kg/kW
1.4 kg/kW
-1.6 kg/kW for MOD 10KTL3-XH
Dimensions
453x505x198 mm
387x425x178 mm
453x505x198 mm vs 387x425x178 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Growatt
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt SPH 10000TL3 BH-UP vs SolarEdge SE10000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt SPH 10000TL3 BH-UP vs Growatt MOD 10KTL3-HU
15 differences, the largest is warranty
Same type, similar size
Huawei
Growatt SPH 10000TL3 BH-UP vs Huawei SUN2000-10KTL-M1
13 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 10KTL3-XH vs Huawei SUN2000-10KTL-M1 (High current version)
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

