Skip to main content
6000T DVM-MPV vs 6000 ES Plus 4 of 14 identical Swap Change inverters

Growatt SPF 6000T DVM-MPV vs Growatt SPF 6000 ES Plus

Growatt SPF 6000T DVM-MPV
Growatt
SPF 6000T DVM-MPV
6 kW Off-grid
VS
Growatt SPF 6000 ES Plus
Growatt
SPF 6000 ES Plus
6 kW Off-grid
The verdict

6000 ES Plus leads on the differences that matter

The largest is max dc voltage: 250 V apart. 4 of 14 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
4 of 14 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 14 parameters
Parameter 6000T DVM-MPV 6000 ES Plus Difference
Max DC voltage 250 V 500 V 250 V apart
Max efficiency 85.0 % 93.0 % 8.0 pp more efficient
Max PV power 5.00 kW 8.00 kW 3.00 kW apart
DC/AC ratio 0.83 1.33 0.50 more oversizing headroom
Weight 52.0 kg 13.5 kg 38.5 kg lighter
Weight per kW 8.7 kg/kW 2.2 kg/kW 6.4 kg/kW lighter
Max operating temperature 45 °C 55 °C 10 °C more heat tolerant
Nominal AC voltage 240 V 230 V 10 V apart
MPPT voltage range 60-245 V 120-450 V 60-245 V vs 120-450 V
Dimensions 540x360x218 mm 395x460x132 mm 540x360x218 mm vs 395x460x132 mm
02

Full specification

Parameter 6000T DVM-MPV 6000 ES Plus Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.00 kW Same
Grid connection - Single-phase Not published by Growatt
Nominal AC voltage 240 V 230 V 10 V apart
Max AC current - - Neither datasheet publishes this
PV input
Max PV power 5.00 kW 8.00 kW 3.00 kW apart
DC/AC ratio 0.83 1.33 +0.50 for 6000 ES Plus
Max DC voltage 250 V 500 V 250 V apart
MPPT voltage range 60-245 V 120-450 V 60-245 V vs 120-450 V
Start voltage - - Neither datasheet publishes this
MPP trackers - 2 Not published by Growatt
Strings per tracker - 1 Not published by Growatt
Max input current per tracker - 16.0 A Not published by Growatt
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 85.0 % 93.0 % +8.0 pp for 6000 ES Plus
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage - 48VDC Not published by Growatt
Max charge current - 80 A Not published by Growatt
Backup power - 6.0 kW Not published by Growatt
Physical
Weight 52.0 kg 13.5 kg -38.5 kg for 6000 ES Plus
Weight per kW 8.7 kg/kW 2.2 kg/kW -6.4 kg/kW for 6000 ES Plus
Dimensions 540x360x218 mm 395x460x132 mm 540x360x218 mm vs 395x460x132 mm
Ingress protection IP20 IP20 Same
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 45 °C 55 °C +10 °C for 6000 ES Plus
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 6000T DVM-MPV vs Growatt SPF 6000T DVM
3 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 6000T DVM-MPV vs Growatt SPF 6000T DVM-G2
8 differences, the largest is max efficiency
Same type, similar size
SMA Solar
Growatt SPF 6000T DVM-MPV vs SMA Solar SI8.0H-13
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.