Growatt SPF 6000T DVM-G2 vs SMA Solar SI8.0H-13
VS
The verdict
SI8.0H-13 leads on the differences that matter
The largest is warranty: 5 yrs longer. 2 of 14 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
2
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 14 parameters
What actually differs
Parameter
SPF 6000T DVM-G2
SI8.0H-13
Difference
Warranty
5 yrs
10 yrs
5 yrs longer
Max DC voltage
250 V
63 V
187 V apart
Max efficiency
93.0 %
95.8 %
2.8 pp more efficient
Max AC power
6.00 kW
11.00 kW
5.00 kW apart
Weight
38.5 kg
63.0 kg
24.5 kg lighter
Weight per kW
6.4 kg/kW
10.5 kg/kW
4.1 kg/kW lighter
Max operating temperature
50 °C
60 °C
10 °C more heat tolerant
Ingress protection
IP20
IP54
IP20 vs IP54
Nominal AC voltage
240 V
230 V
10 V apart
MPPT voltage range
60-200 V
41-63 V
60-200 V vs 41-63 V
Battery voltage
48 VDC
41-63 V (48 V nominal)
48 VDC vs 41-63 V (48 V nominal)
Dimensions
650x365x247 mm
612x467x242 mm
650x365x247 mm vs 612x467x242 mm
02
Full specification
Parameter
SPF 6000T DVM-G2
SI8.0H-13
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.00 kW
11.00 kW
5.00 kW apart
Grid connection
-
Single-phase
Not published by Growatt
Nominal AC voltage
240 V
230 V
10 V apart
Max AC current
-
120.0 A
Not published by Growatt
PV input
Max PV power
4.50 kW
-
Not published by SMA Solar
DC/AC ratio
0.75
-
Not published by SMA Solar
Max DC voltage
250 V
63 V
187 V apart
MPPT voltage range
60-200 V
41-63 V
60-200 V vs 41-63 V
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
1
-
Not published by SMA Solar
Strings per tracker
1
-
Not published by SMA Solar
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
93.0 %
95.8 %
+2.8 pp for SI8.0H-13
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
48 VDC
41-63 V (48 V nominal)
48 VDC vs 41-63 V (48 V nominal)
Max charge current
60 A
-
Not published by SMA Solar
Backup power
6.0 kW
-
Not published by SMA Solar
Physical
Weight
38.5 kg
63.0 kg
-24.5 kg for SPF 6000T DVM-G2
Weight per kW
6.4 kg/kW
10.5 kg/kW
-4.1 kg/kW for SPF 6000T DVM-G2
Dimensions
650x365x247 mm
612x467x242 mm
650x365x247 mm vs 612x467x242 mm
Ingress protection
IP20
IP54
IP20 vs IP54
Cooling
-
-
Neither datasheet publishes this
Noise
-
-
Neither datasheet publishes this
Max operating temperature
50 °C
60 °C
+10 °C for SI8.0H-13
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
5 yrs
10 yrs
+5 yrs for SI8.0H-13
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt SPF 6000T DVM-G2 vs Growatt SPF 6000T DVM
8 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 6000T DVM-G2 vs Growatt SPF 6000T DVM-MPV
8 differences, the largest is max efficiency
Same type, similar size
Growatt
Growatt SPF 6000T DVM-G2 vs Growatt SPF 6000 ES Plus
12 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.