Skip to main content
5000TL HVM vs 5000 ES 8 of 15 identical Swap Change inverters

Growatt SPF 5000TL HVM vs Growatt SPF 5000 ES

Growatt SPF 5000TL HVM
Growatt
SPF 5000TL HVM
5 kW Off-grid
VS
Growatt SPF 5000 ES
Growatt
SPF 5000 ES
5 kW Off-grid
The verdict

5000 ES leads on the differences that matter

The largest is max dc voltage: 305 V apart. 8 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
8 of 15 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 15 parameters
Parameter 5000TL HVM 5000 ES Difference
Max DC voltage 145 V 450 V 305 V apart
Max PV power 4.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 0.90 1.20 0.30 more oversizing headroom
MPPT voltage range 30-115 V 120-430 V 30-115 V vs 120-430 V
Battery voltage 24VDC or 48VDC (model-dependent) 48VDC 24VDC or 48VDC (model-dependent) vs 48VDC
Weight 11.5 kg 12.0 kg 0.5 kg lighter
Dimensions 455x350x130 mm 485x330x135 mm 455x350x130 mm vs 485x330x135 mm
02

Full specification

Parameter 5000TL HVM 5000 ES Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.00 kW 5.00 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current - - Neither datasheet publishes this
PV input
Max PV power 4.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 0.90 1.20 +0.30 for 5000 ES
Max DC voltage 145 V 450 V 305 V apart
MPPT voltage range 30-115 V 120-430 V 30-115 V vs 120-430 V
Start voltage - - Neither datasheet publishes this
MPP trackers - 1 Not published by Growatt
Strings per tracker - 1 Not published by Growatt
Max input current per tracker - - Neither datasheet publishes this
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 93.0 % 93.0 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 24VDC or 48VDC (model-dependent) 48VDC 24VDC or 48VDC (model-dependent) vs 48VDC
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 11.5 kg 12.0 kg -0.5 kg for 5000TL HVM
Weight per kW 2.3 kg/kW 2.4 kg/kW Effectively the same
Dimensions 455x350x130 mm 485x330x135 mm 455x350x130 mm vs 485x330x135 mm
Ingress protection - IP20 Not published by Growatt
Cooling - - Neither datasheet publishes this
Noise - - Neither datasheet publishes this
Max operating temperature 55 °C 55 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Growatt
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt SPF 5000TL HVM vs Growatt SPF 5000T DVM
8 differences, the largest is max efficiency
Same type, similar size
Growatt
Growatt SPF 5000TL HVM vs Growatt SPF 5000T DVM-MPV
10 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 5000TL HVM vs Growatt SPF 3500 ES Lite
6 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 5000 ES vs Growatt SPF 5000 ES Lite
6 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.