Growatt SPF 3000TL LVM-ES vs Easun Power ISolar SMV 3K-24
VS
The verdict
ISolar SMV 3K-24 leads on the differences that matter
The largest is max dc voltage: 105 V apart. 5 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
5
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 15 parameters
What actually differs
Parameter
SPF 3000TL LVM-ES
ISolar SMV 3K-24
Difference
Max DC voltage
250 V
145 V
105 V apart
Max PV power
4.00 kW
1.00 kW
3.00 kW apart
DC/AC ratio
1.33
0.33
1.00 more oversizing headroom
Max charge current
40 A
120 A
80 A faster charging
Weight
12.0 kg
6.5 kg
5.5 kg lighter
Weight per kW
4.0 kg/kW
2.2 kg/kW
1.8 kg/kW lighter
Nominal AC voltage
120 V
230 V
110 V apart
MPPT voltage range
120-250 V
17-115 V
120-250 V vs 17-115 V
Battery voltage
48VDC
12 VDC / 24 VDC / 48 VDC (model-dependent)
48VDC vs 12 VDC / 24 VDC / 48 VDC (model-dependent)
Dimensions
470x320x135 mm
440x300x100 mm
470x320x135 mm vs 440x300x100 mm
02
Full specification
Parameter
SPF 3000TL LVM-ES
ISolar SMV 3K-24
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
120 V
230 V
110 V apart
Max AC current
-
-
Neither datasheet publishes this
PV input
Max PV power
4.00 kW
1.00 kW
3.00 kW apart
DC/AC ratio
1.33
0.33
+1.00 for SPF 3000TL LVM-ES
Max DC voltage
250 V
145 V
105 V apart
MPPT voltage range
120-250 V
17-115 V
120-250 V vs 17-115 V
Start voltage
-
-
Neither datasheet publishes this
MPP trackers
1
-
Not published by Easun Power
Strings per tracker
1
-
Not published by Easun Power
Max input current per tracker
-
-
Neither datasheet publishes this
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
90.0 %
-
Not published by Easun Power
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
48VDC
12 VDC / 24 VDC / 48 VDC (model-dependent)
48VDC vs 12 VDC / 24 VDC / 48 VDC (model-dependent)
Max charge current
40 A
120 A
+80 A for ISolar SMV 3K-24
Backup power
3.0 kW
-
Not published by Easun Power
Physical
Weight
12.0 kg
6.5 kg
-5.5 kg for ISolar SMV 3K-24
Weight per kW
4.0 kg/kW
2.2 kg/kW
-1.8 kg/kW for ISolar SMV 3K-24
Dimensions
470x320x135 mm
440x300x100 mm
470x320x135 mm vs 440x300x100 mm
Ingress protection
IP20
-
Not published by Easun Power
Cooling
-
-
Neither datasheet publishes this
Noise
-
-
Neither datasheet publishes this
Max operating temperature
50 °C
50 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Easun Power
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt SPF 3000TL LVM-ES vs Growatt SPF 3000 ES
7 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 3000TL LVM-ES vs Growatt SPF 3000TL HVM-24
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt SPF 3000TL LVM-ES vs Growatt SPF 3000TL HVM-48
11 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.